Laserfiche WebLink
T93 • ' <br /> Fuel Oxygenates Analytical Data <br /> ConocoPhillips(Farmer BP) Station No 11193 <br /> 3202 W Hammer Lane, Stockton,California <br /> Well Date of MtBE DIPE EtBE TAME EDC EDB TBA Methanol Ethanol <br /> ID Sampling (ug/L) (ug/L) (ug/L) (ug/L) (ug1L) (ug/L) (ug/L) (ug/L) (ug/L) <br /> MW-2R 7/14/2000 31,000 2 18 69 ND<l0 ND<l0 -- 6,300 ND<1000 <br /> 10/27/2000 130,000 ND<2000 ND<2000 ND<2000 ND<2000 ND<2000 48,000 100,000 ND<1000 <br /> 7/29/2002 9,590 ND<20[1] 16[1] 13[1] ND<10[l] ND<10[1] 28,000[1] -- <br /> 9/11/2002 11,000 ND<250 ND<250 ND<250 ND<250 ND<250 42,000 --- ND<20,000 <br /> 4/7/2003 160 ND<10 ND<10 ND<10 ND<10 ND<10 8,200 --- ND<2,500 <br /> 6/27/2003 340 ND<20 N0<20 ND<20 ND<20 ND<20 33,000 — ND<5,000 <br /> VW-1 10/27/2000 190,000 ND<2000 ND<2000 ND<2000 ND<2000 ND<2000 64000 50,000 ND<1000 <br /> 7/29/2002 33,900 ND<400[1] ND<400[1] ND<400[1] ND<200[1] ND<200[1] 71,000[1] --- --- <br /> 9/11/2002 55,000 ND<500 ND<500 ND<500 ND<500 ND<500 93,000 --- ND<40,000 <br /> 4/7/2003 220 ND<20 21 ND<20 ND<20 ND<20 30,000 --- ND<5,000 <br /> 6/27/2003 380 ND<40 ND<40 ND<40 ND<40 ND<40 75,000[3] — ND<10,000 <br /> Notes <br /> [1] Analysis conducted beyond EPA recommended hold time <br /> [2] Lab reports significant headspace in the VOA vial <br /> Analysis conducted in excess of EPA recommended hold time <br /> [3] Result reflects reanalysis of the sample,which was conducted beyond EPA recommended hold time, initial result of 90,000 ppb was reported <br /> within hold time as an estimate beyond the calibration range of the instrument <br /> MtBE Methyl tertiary butyl ether <br /> DIPS Di Isopropyl Ether <br /> EDB 1,2-Dibromoethane or Ethylene Dibromide <br /> EDC 1,2-Dichloroethane <br /> EtBE Ethyl tertiary Butyl Ether <br /> TBA tertiary Butyl Alcohol <br /> 11ConocoPhillipslTosco Marketmg1111931Tables111193 20MR03 xls Page 3 of 3 <br />