Laserfiche WebLink
• • i 9s <br /> Table 1 <br /> Ozone Injection-System Operational Data <br /> 76 Service Station No 11193 <br /> 3202 West Hammer Lane Stockton California <br /> w Ax; ;' ?' w d,OZONE SPARGE SYSTEM _ OZ-1" OZ-2 OZ-3 OZ-4 OZ-5 OZ-6 OZ-7 OZ-8 OZ-9 OZ-10 <br /> a, <br /> i4 Y T <br /> r SystemstdtUS <br /> '§t E z,Penod Cumm <br /> (ON/OFF),'a,,'H6urrneterJ Online Online Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure <br /> i�Dati ibr .-: Nc til-- 'Amval; Departure - Readln ,1 Factor. Factor (psi) (psi) (psi) (psi) (PSI) 1 (PSI) (psi) (psi) (psi) (psi) <br /> 05/25/04 a Off On 7526 000 000 -- -- -- -- — — — — — -- <br /> 06/16/04 On On 53433 098 1 14 35 35 30 33 32 35 34 29 27 24 <br /> 07/29/04 b Off On 130291 084 094 33 36 27 28 30 34 34 28 25 26 <br /> 08/19/04 c Off Off 131034 002 071 -- -- -- -- — — — — — -- <br /> 09/16/04 b Off On 1721 58 069 071 38 36 33 33 33 36 35 29 27 24 <br /> Sparge time per cycle mm 7 1 7 1 7 1 7 1 7 7 7 1 7 1 7 1 7 <br /> Reporting Period 06116104 to 09/16/04 <br /> Total flours Operational 1,722 <br /> Total Pounds Ozone Injected 15 <br /> Period Hours Operational 1187 <br /> Period Percent Operational 60% <br /> Period Pounds Ozone Injected 11 <br /> Definitions <br /> psi Pounds per square inch <br /> — Data not available <br /> Cumm Cummulative <br /> Notes <br /> System cycles through program 18 times per day,for 87 5%utilization <br /> a =System startup <br /> b =Ozone sensor tripped <br /> c =System down due to compressor failure <br />