Laserfiche WebLink
Standard Procedure for Groundwater Sampling—Petroleum Hydrocarbons (continued) <br /> Page 2 of 2 <br /> Trip Blanks <br /> To assure the quality of the collected samples and to evaluate the potential for cross contamination <br /> during transport to the laboratory, a distilled-water trip blank accompanies the samples in the cooler <br /> The trip blank Is analyzed for the presence of volatile organic compounds of concern For petroleum <br /> hydrocarbons, the trip blank Is typically analyzed for TPHg, BTEX, and MtBE by EPA Method 8260 <br /> Containment and Disposal of Generated Water/LPH <br /> All wastewater, purge water and LPH (1f present) generated during the field activities are retained on- <br /> site In appropriate containers (I e DOT-approved drums or bulk tanks) for future disposal All <br /> wastewater 1s delivered under appropriate manifest to a facility certified and licensed to receive such <br /> waste streams <br /> Related Procedures <br /> • Standard Procedure for Equipment Decontamination <br /> 1 1ConocoPhdlipslTosco Marketing1111931QMR12QMR44 Final doe <br />