Laserfiche WebLink
Ito <br /> Tosco Corporation,a subsidiary of Phillips Petroleum Company 5 <br /> Tosco Station#11193,3202 West Hammer Lane,Stockton CA March 7 2002 <br /> vacuum, vapor extraction flow rates, groundwater extraction flow rates, and influent FID <br /> readings are presented in Table 1 <br /> During the 2-hour DPE event for well VW-1, the applied vacuum was 25 in of Hg, vapor <br /> extraction flow rates ranged from 13 08 cfm to 15 26 cfm Groundwater elevations for <br /> wells MW-1R and MW-2R decreased by 0 01 feet, wells MW-8 and MW-5 increased by <br /> 0 01 feet, and well MW-9 did not show any change in groundwater elevation FID <br /> readings collected from the vapor extracted ranged from 1,000 ppmv to 15,000 ppmv <br /> Applied vacuum, vapor extraction flow rates, groundwater extraction flow rates, and <br /> influent FID readings are presented in Table 1 <br /> During the 92-hour DPE event for wells VW-1, MW-2R, and MW-1R, the applied <br /> vacuum ranged from 14 in of Hg to 25 in of Hg, and vapor extraction flow rates ranged <br /> from 13 86 cfm to 42 86 cfm The groundwater extraction flow rates ranged from 0 01 <br /> gpm to 6 2 gpm Groundwater elevations for well MW-5 decreased by 0 01 feet and <br /> wells MW-4, MW-8, MW-3 and MW-9 increased by 0 02 feet, 0 04 feet, 0 03 feet, and <br /> 0 03 feet, respectively FID readings collected from the vapor extracted from all wells <br /> were initially 500 ppmv and decreased to 150 ppmv by the end of the test Applied <br /> vacuum, vapor extraction flow rates, groundwater extraction flow rates, and influent FID <br /> readings are presented in Table 1 <br /> LABORATORY ANALYTICAL DATA <br /> Laboratory analyses of soil vapor samples collected during the DPE tests are summarized <br /> in Table 2 and shown graphically on Figure 2 As shown on Figure 2, TPHg influent <br /> concentrations declined from 300 ppmv to 100 ppmv, benzene concentrations declined <br /> from 5 3 ppmv to 3 7 ppmv, and MtBE influent concentrations declined from 200 ppmv <br /> to 86 ppmv <br /> Groundwater samples were collected from wells MW-1R, MW-2R, and VW-1 before and <br /> after DPE testing Below is a table showing the groundwater concentrations of TPHg, <br /> benzene, and MtBE in parts per billion (ppb) measured before and after the DPE event <br /> Refer to Table 3 for a more complete list showing all analyte concentrations The bolded <br /> values indicate reduced analyte concentrations <br /> Well# TPHg (lvb) kle"erre(pleb) MtOE(pph) <br /> Before DPE After DPE Before DPE After DPE Before DPE After DPE <br /> .VW 1 <100,000 <50,000 <1,000 810 140 000 71,000 <br /> MW IR <100 <50 <1 0 <0 50 220 160 <br /> MW 2R <50,000 <2,000 <500 76 64,000 7,700 <br /> DPE Mass Removal Rates <br /> The total mass of TPHg, benzene, and MTBE removed during the test were estimated <br /> using the influent air analytical results, an average well field flow rate, and the time <br />