My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS_FILE 1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
3500 - Local Oversight Program
>
PR0545252
>
WORK PLANS_FILE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2020 12:11:07 PM
Creation date
1/31/2020 11:05:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
FileName_PostFix
FILE 1
RECORD_ID
PR0545252
PE
3528
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #3132*
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
071-180-20
CURRENT_STATUS
02
SITE_LOCATION
3555 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County DIRECTOR <br /> Donna <br /> ogqu" ro Environmental Health Department ASSlSTASSISTA eram,REHS <br /> NTD/RECTOR <br /> 600 East Main Street Laude corolla,REHS <br /> Stockton, California 95202-3029 " <br /> -PROGRAM COORDINATORS <br /> Mlke Huggins,REHS,RDI <br /> Margaret Lagodo,REHS <br /> Webslte;www.Sfgov.Org/ehd Robert McClellan,REHS <br /> Phone: (209)469-3420 Jeff Canuesco,REHS,RDI <br /> Fax: (209)464-0139 Kasey Foley,REHS <br /> L <br /> Tune 5,2009 <br /> L <br /> Mr.Michael Karvelot L <br /> Quik Stop Markets,Incorporated <br /> 4567 Enterprise Street <br /> Fremont,California 94538 <br /> Subject: Quik Stop Market No.132 !I <br /> i, 3555 West Hammer Lane <br /> Stockton,California 95209 <br /> = The San Joaquin County Environmental Health Department (EHD) has reviewed Additional <br /> L Investigation Work Plan dated May 18, 2009, prepared by ATC Associates Inc. (ATC) for the <br /> above-referenced site on your behalf. The work plan was submitted in response to a letter dated <br /> September 23, 2008, from the EHD directing you to address: the lateral extent of petroleum <br /> hydrocarbon contaminatipn in the first water-bearing zone identified by the EHD to be <br /> approximately five to ten-feet below surface grade (bsg); the vertical extent of petroleum . <br /> hydrocarbon contamination in groundwater near soil borings ATC-5 and SB-2 where methyl <br /> tertiary-butyl ether(1vffBE) was detected at 39 micrograms per liter I <br /> gr p (µg/L) at Forty-two feet bsg, <br /> and 500 itgtL at twenty-nine feet bsg, respectively; and the petroleum hydrocarbon contamination <br /> remaining in soil in the area of soil sample QS-2 collected at approximately ten feet bsg. <br /> In the work plan,ATC proposes to advance three soil borings.(SB-4, SB-5, and SB-6) to address <br /> soil and groundwater data gaps that include: <br /> • Evaluation of the "horizontal" and 'lateral" extent of impacted groundwater near the <br /> L former underground storage tanks(USTs), <br /> • Evaluation of the potential for methyl tertiary-butyl ether (MTBE) to migrate down <br /> gradient of the source area beneath the adjacent Taco Bell facility to the southeast,and <br /> • Evaluation of impacted soil that may remain near the original release at the north end of <br /> ar the pump island. <br /> ATC proposes to advance borehole SB-4 approximately eight feet easttnortheast of soil boring B-3, <br /> L initially to an approximate depth of fifteen feet bsg. One soil sample is proposed to be collected at <br /> the capillary fringe,and one grab groundwater sample is proposed to be collected at approximately <br /> fifteen feet bsg. Then ATC proposes to advance the boring to approximately forty feet and collect a <br /> grab groundwater sample. The site map illustrating the proposed location for SB4 does not include <br /> L the approximate location where soil sample QS-2 was collected. Based on information on file at <br /> the EHD, the proposed location fur SB-4 is not where soil sample QS-2 was collected; therefore, <br /> you must provide technical justification for the proposed sampling point for SB-4, collection of a <br /> L grab groundwater sample at approximately fifteen feet bsg, and collection of a soil sample at the 1 } <br /> capillary fringe. <br /> I <br /> � a <br /> 1 <br /> i <br /> L <br />
The URL can be used to link to this page
Your browser does not support the video tag.