Laserfiche WebLink
FIELD PROTOCOL <br /> The static water level and floatingroduct level in each we <br /> P � if present, well that contained water was measured <br /> with an ORS Interphase Probe Model No 1068018 or Solorust Water Level Indicator, these instruments are <br /> ' accurate to the nearest 0 01 foot These groundwater depths were subtracted from wellhead elevations, <br /> including corrections for product thickness, when necessary, for gradient evaluation by multiplying product <br /> ' thickness (PT) by a correction factor 0 8 and subtracting from the DTW (Adjusted DTW = DTW - [PT x <br /> 0 8]) <br /> ' Water samples collected for subjective evaluation were collected by gently Iowering approximately half the <br /> length of a new disposable or Teflon@ bailer past the air-water interface (if possible) and collecting a sample <br /> from near the surface of the water in the well The samples were checked for measurable floating <br /> hydrocarbon product All Teflon® bailers are triple washed with Alconox® and triple rinsed with distilled <br /> water prior to use <br /> Before water samples were collected from the groundwater Monitoring Wells, the wells were purged until <br /> stabilization of the temperature, pH, and conductivity were obtained Approximately three well casing <br /> volumes were purged before those characteristics stabilized The quantity of water purged from each well <br /> ' was calculated as follows <br /> 1 well casing volume =pr�h(7 48) where <br /> ' r=radius of the well casing in feet <br /> h= column of water in the well in feet <br /> ' (depth to bottom - depth to water) <br /> 7 48 = conversion constant from cubic feet to gallons <br /> Gallons of water purged/gallons in 1 well casing volume=well casing volumes removed <br /> 1 After purging, each well was allowed to recharge to at least 80% of the initial water level Water samples <br /> were collected with a new disposable or Teflon® bailer, and carefully poured into 40-milliliter (ml) glass <br /> ' vials, which were filled so as to produce a positive meniscus Each vial was preserved with hydrochloric <br /> acid, sealed with a cap containing a Teflon® septum and subsequently examined for air bubbles to avoid <br /> ' headspace which would allow volatilization to occur The samples were promptly transported in iced <br /> storage in a therinally-insulated ice chest accompanied by a Chain of Custody Record, to a California- <br /> certified laboratory <br /> 1 798 kat Quaner Groundwater Monitoring Report <br /> ATC 11LSPSPLEAS%NTONVdmm rasLlLE]IRNiAN4QUIKSrop11)2198rpt Is[dO [Nta%_'8 INS] <br />