Laserfiche WebLink
� <br /> APPENDIX A <br /> FIELD PROTOCOL <br /> The static water level and floating product level, if present, in each well that contained water <br /> was measured with an ORS Interphase Probe Model No 1068018 or Solornst Water Level <br /> Indicator, these instruments are accurate to the nearest 0 01 foot These groundwater <br /> ' depths were subtracted from wellhead elevations, including corrections for product <br /> thickness, when necessary, for gradient evaluation by multiplying product thickness (PT) by <br /> a correction factor 0 8 and subtracting from the DTW (Adjusted DTW = DTW-[PT x 0 81) <br /> Water samples collected for subjective evaluation were collected by gently lowering <br /> approximately half the length of a new disposable or Teflon® bailer past the air-water <br /> interface (if possible) and collecting a sample from near the surface of the water in the well <br /> The samples were checked for measurable floating hydrocarbon product All Teflon® <br /> bailers are triple washed with Alconox®and triple rinsed with distilled water prior to use <br /> Before water samples were collected from the groundwater Monitoring Wells, the wells <br /> were purged until stabilization of the temperature, pH, and conductivity were obtained <br /> Approximately three well casing volumes were purged before those characteristics <br /> stabilized The quantity of water purged from each well was calculated as follows <br /> 1 well casing volume = Tcr2h(7 48) where <br /> r--radius of the well casing in feet <br /> h=column of water in the well in feet <br /> (depth to bottom - depth to water) <br /> 7 48=conversion constant from cubic feet to gallons <br /> Gallons of water purged/gallons in 1 well casing volume = well casing volumes removed <br /> After purging, each well was allowed to recharge to at least 80% of the initial water level <br /> Water samples were collected with a new disposable or Teflon® bailer, and carefully <br /> poured into 40-milliliter (ml) glass vials, which were filled so as to produce a positive <br /> meniscus Each vial was preserved with hydrochloric acid, sealed with a cap containing a <br /> Teflon® septum, and subsequently examined for air bubbles to avoid headspace which <br /> would allow volatilization to occur The samples were promptly transported in iced storage <br /> in a thermally-insulated ice chest, accompanied by a Chain of Custody Record, to a <br /> Califomia-certified laboratory <br /> • <br /> SWTH <br /> MVkw%94.2731gwk 132 apa(3114197] <br />