My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0003755
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAZELTON
>
375
>
2900 - Site Mitigation Program
>
PR0540905
>
ARCHIVED REPORTS_XR0003755
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 10:09:16 AM
Creation date
2/3/2020 8:56:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0003755
RECORD_ID
PR0540905
PE
2960
FACILITY_ID
FA0023406
FACILITY_NAME
SIERRA LUMBER MANUFACTURERS
STREET_NUMBER
375
Direction
W
STREET_NAME
HAZELTON
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
147120808
CURRENT_STATUS
01
SITE_LOCATION
375 W HAZELTON AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I 1 <br /> i I <br /> 11 ' ' i t ' h , <br /> I 1 <br /> 15 December 2003 <br /> AGE-NC Project No 98-0448 <br /> Page 2 of 9 <br /> - <br />' stabilization at regular purge-volume intervals from each well using an Oakton water analyzer Field <br /> data and logs are provided in Appendix A Purged ground water was contamenzed in properly <br /> labeled DOT-approved 55-gallon drums and was stored on-site in an area lacking general public <br /> access _ <br /> I <br /> Dual-completion monitoring well MW-4A and MW-4B were purged utilizing a Watera Hydro-Lift <br /> U pump equipped with a mechanical arm by lowering and raising a 3/e-inch outer diameter, length- <br /> discrete polyethylene hose equipped with a ball-valve water tip through the top chambers into the <br /> A <br /> specific water-charged screened section Approximately 6 to 13 gallons of ground water(a minimum <br /> " of three casing-water volumes per well)were purged from each well location Temperature,pH and <br /> conductivity were measured for stabilization at regularpurge-volume intervals from each well using, <br /> an Oak-ton water analyzer Field data and logs are provided in Appendix A Purged ground water was, <br /> containerized in properly labeled DOT-approved 55-gallon drums and was stored on-site in an area <br /> lacking general public access - <br /> 2 2 GROUND WATER SAMPLING <br /> • Following well purging, the ground water level in each of the purged wells was allowed to achieve <br /> a minimum of 80%recharge prior to sample collection Groundwater samples were collected from <br /> the purged wells utilizing new,disposable polyethylene bailers,groundwater samples were collected <br /> from the purged wells MW-4A and MW-4B utilizing 3/e-inch diameter polyethylene tubing and <br /> transferred into 40-m1 EPA-approved volatile organic analysis (VOA)vials containing 0 5,rill 18% <br /> h'ydrochlonc,acid as a sample preservative Care was taken to ensure that visible air,bubbles were 4 <br /> not present in the vials after filling and capping Ground water sample containers were labeled with <br /> the well designation, date, time, and sampler's initials ' <br /> 23 LABORATORY ANALYSIS OF GROUND WATER SAMPLES <br /> Each ground water sample was logged on a.ch_ain_-of-custody form, placed a chilled container and _ <br /> ` transported to CalTech Environmental Laboratories (CTEL), a California Department of Health <br /> Services (DHS)-certified laboratory for analysis for _ <br /> • Total petroleum hydrocarbons quantified as gasoline (TPH-g) by EPA Method 8015 <br /> Modified,, <br /> 5 I <br /> , � I <br /> • Benzene, toluene, ethylberizene and xylene (BTEX) by EPA Method 8260B, and <br /> ' I i <br /> Advanced GeoEnvironmental,Inc <br /> iy i <br />
The URL can be used to link to this page
Your browser does not support the video tag.