Laserfiche WebLink
I 1 <br /> i I <br /> 11 ' ' i t ' h , <br /> I 1 <br /> 15 December 2003 <br /> AGE-NC Project No 98-0448 <br /> Page 2 of 9 <br /> - <br />' stabilization at regular purge-volume intervals from each well using an Oakton water analyzer Field <br /> data and logs are provided in Appendix A Purged ground water was contamenzed in properly <br /> labeled DOT-approved 55-gallon drums and was stored on-site in an area lacking general public <br /> access _ <br /> I <br /> Dual-completion monitoring well MW-4A and MW-4B were purged utilizing a Watera Hydro-Lift <br /> U pump equipped with a mechanical arm by lowering and raising a 3/e-inch outer diameter, length- <br /> discrete polyethylene hose equipped with a ball-valve water tip through the top chambers into the <br /> A <br /> specific water-charged screened section Approximately 6 to 13 gallons of ground water(a minimum <br /> " of three casing-water volumes per well)were purged from each well location Temperature,pH and <br /> conductivity were measured for stabilization at regularpurge-volume intervals from each well using, <br /> an Oak-ton water analyzer Field data and logs are provided in Appendix A Purged ground water was, <br /> containerized in properly labeled DOT-approved 55-gallon drums and was stored on-site in an area <br /> lacking general public access - <br /> 2 2 GROUND WATER SAMPLING <br /> • Following well purging, the ground water level in each of the purged wells was allowed to achieve <br /> a minimum of 80%recharge prior to sample collection Groundwater samples were collected from <br /> the purged wells utilizing new,disposable polyethylene bailers,groundwater samples were collected <br /> from the purged wells MW-4A and MW-4B utilizing 3/e-inch diameter polyethylene tubing and <br /> transferred into 40-m1 EPA-approved volatile organic analysis (VOA)vials containing 0 5,rill 18% <br /> h'ydrochlonc,acid as a sample preservative Care was taken to ensure that visible air,bubbles were 4 <br /> not present in the vials after filling and capping Ground water sample containers were labeled with <br /> the well designation, date, time, and sampler's initials ' <br /> 23 LABORATORY ANALYSIS OF GROUND WATER SAMPLES <br /> Each ground water sample was logged on a.ch_ain_-of-custody form, placed a chilled container and _ <br /> ` transported to CalTech Environmental Laboratories (CTEL), a California Department of Health <br /> Services (DHS)-certified laboratory for analysis for _ <br /> • Total petroleum hydrocarbons quantified as gasoline (TPH-g) by EPA Method 8015 <br /> Modified,, <br /> 5 I <br /> , � I <br /> • Benzene, toluene, ethylberizene and xylene (BTEX) by EPA Method 8260B, and <br /> ' I i <br /> Advanced GeoEnvironmental,Inc <br /> iy i <br />