Laserfiche WebLink
' Mass-Volume Calculations Of Extracted Gasoline Hydrocarbons - Continued <br /> SIERRA LUMBER - 375 West Hazelton Avenue, Stockton, CA <br />' 4. 13 December 2001 to 10 January 2002 <br />' The average analytical TPH-g concentration for this tune interval was deternimed to be 199,ug/1(12-13-01=88Fzgll and <br /> 01-10-02=3 10,cg/l, avg = 199 ugll) The average flow rates during this time was calculated at 0 35 inches of water <br /> or approximately 34 cubic feet per minute(table 5),the operational period was equal to 672 hours of running time <br />' C = 199 4g/1=0 000199 kg/n 3 <br /> Q = 0 35 inches water= 34 ft3/min <br /> t=672 hours <br />' Converting Q to ml/hour yields <br />' Q =(34 ft'/mm) •(60 mm/hour) •(0 0283168rn3/ft) =57 76 ml/hour <br /> M=C - Q •t=(0 000199 kg/m') •(57 76 m'Ihour) • (672 hours)=7 72 kg of gasoline <br /> Converting kg of gasoline to pounds of gasoline yields <br /> 7 72 kg of gas • 2 2046 lbs of gas/kg of gas= 17 03 lbs of gasoline <br />' Converti ig pounds of gasoline to gallons of gasoline yields <br /> 17 03 lbs of gas • 0 16 gal of gas/lbs of gas = =2.72 gallons of gasoline <br /> 10) <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> 1 <br /> i <br />