t <br /> 03 September 2004 <br /> AGE-NC Project No' 98-0448 <br />' Page 8 of 13 <br /> r <br />' 3 3 2 ANALYTICAL RESULTS OF SOIL-GAS VAPOR SAMPLES <br /> Influent SVE air flow samples were collected on 23 February,27 April,26 May,03 June and 22 June <br />' 2004, additionally, one effluent sample was collected on 22 June 2004 From the above samples, <br /> TPH-g was detected at 3,500 µg/l and 960 µg/l in the Influent SVE air flow samples collected on 03 <br /> June and 22 June 2004,respectively TPH-g was detected at 100µg/1 in the effluent sample collected <br />' on 22 June 2004 <br /> Various BTEX compounds were detected from the 03 June and 22 June Influent SVE air flow <br />' samples at concentrations as high as 2 1 µg/1 benzene, 16 gg/l toluene, 19 pg/l ethylbenzene and 10 <br /> µg/1 xylenes Benzene was detected from the 22 June effluent sample at a concentration of 1 3 gg/l <br />' Analytical results of SVE air flow samples are summarized in Table 5 The laboratory reports(CTEL <br /> Project Nos 0402-137, 0404-195,0405-171, 0406-031 and 0406-212) and chain of custody forms <br />' are presented in Appendix G A plot of influent TPH-g SVE air flow concentrations versus time is <br /> presented in Appendix H <br /> 3 3 3 MASS CALCULATION OF RECOVERED PRODUCT <br /> I The hydrocarbon mass removed during the SVE operating period was calculated using the following <br /> equation M = C•Q•t <br /> I where M= cumulative mass recovered (kg) <br /> C =vapor concentration (kg/m3) <br /> Q = extraction flow rate (M3/hr) <br /> t = operational period, in hours <br /> Between 28 January to 10 March 2004 and between 20 April to 22 June 2004, the SVE unit <br /> I continuously operated approximately 2,520 hours The average of analytical results between SVE <br /> air flow sampling events(Table 5), average SVE air flow rates(Table 3) and the operational period <br /> were used to calculate the approximate volume and mass of extracted gasoline during these periods <br /> I During the above air monitoring events, the mass of hydrocarbons extracted from the SVE system <br /> Y Y <br /> was calculated to be approximately 108 pounds, or equivalent to an approximate volume of 17 25 <br /> Igallons of gasoline extracted A plot of the cumulative volume(gallons) of hydrocarbons extracted <br /> to date is in Appendix H Added to the estimated 253 36 gallons of hydrocarbons extracted from the <br /> SVE system since 16 April 2001,the total volume of hydrocarbons extracted to date is estimated at <br /> 270 61 gallons The mass/volume calculations for extracted hydrocarbons are included in <br /> Appendix I <br /> IAdvanced GeoEnvironmental,Inc <br /> I <br />