Laserfiche WebLink
SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 E. Main St. • Stockton, CA 95202-3029 • Phone(209)468-3420 <br /> Donna Heran,R.E.H.S., Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> PrNumberam--- Permit <br /> ;e <br /> Iold ID Progr n Code and Description Valid <br /> X0513609 PTOIl09804 -SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/1/2012 To 12/31/2012 <br /> Hazardous-Waste Generator Program: <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20,Chap.6.5,Art.2-13, <br /> Sec.25100 et seq,and Title 22,California Code of Regulations,Chap.20_ <br /> ---- - - ------------------------------------------------------------------------------------ <br /> PR0231310 2300-UNDERGROUND STORAGE TANK FACILITY 1/1/2012 To 12/31/2012 <br /> Underground Storage Tank Program: <br /> California Health and Safety Code,Div.20,Chap.6.7 and Title 23,California Code of Regulations,Chap_ 16._ <br /> ---------- ------ --------- -- ---------- ------ -------- ------------ ----- - --------- <br /> P/E Tank# Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection <br /> 2362 13 390002313100131013 PT0004724 8,000 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 14 390002313100131014 PT0004725 8,000 DIESEL Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 15 390002313100131015 PT0004726 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 16 390002313100131016 PT0004727 10,000 DIESEL Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 17 390002313100131017 PT0004728 10,000 DIESEL Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions <br /> established by San Joaquin County. <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved <br /> monitoring,response,and plot plans shall be maintained onsite with the permit. <br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit. <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the requirements of Title 23 CCR,Chap. 16,An.5,and the approved Emergency Response Plan. <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was <br /> performed. <br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 1 1) Construction,repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment. <br /> 12) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. <br /> 13) A"Conditional'Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated. <br /> PERMITS TO OPERATE may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: VAN DE POL ENTERPRISES INC. <br /> Tank Owner: THORPE,JIM OIL INC <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility: VAN DE POL ENT INC/PACIFIC PRIDE Facility ID FA0003773 <br /> 351 N BECKMAN RD Account ID AR0003353 <br /> LODI CA 95241 Issued 2/10/2012 <br /> Billing Address: ATTN SHACKELFORD, TED <br /> VAN DE POL ENT INC/PACIFIC PRIDE <br /> PO BOX 1107 <br /> STOCKTON CA 95201-1107 <br /> 7023.rpt <br />