ARCHIVED REPORTS_XR0002607
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15600
>
3500 - Local Oversight Program
>
PR0545273
>
ARCHIVED REPORTS_XR0002607
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 6:12:11 PM
Creation date
2/3/2020 11:16:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002607
RECORD_ID
PR0545273
PE
3528
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
02
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
=MZjitonngell Elevation of PVC Depth to Groundwater Elevation of Gradient Direction <br /> Groundwater <br /> i MW-6 9120100 14 75 feet 8 99 feet +576 Northeast <br /> MW-6 12/27/00 14 75 feet 9 81 feet +494 North <br /> MW-6 7130101 14 75 feet 9 20 feet +555 East/Northeast <br /> I <br /> MW-6 1115101 14 75 feet 10 15 feet +460 East <br /> 1 MW-6 2127102 14 75 feet 8 73 feet +602 East <br /> MW-6 5/21102 1 14 75 feet 9 01 feet +574 East <br /> MW-6 8/29102 14 75 feet 9 27 feet 1 +548 1 East <br /> 1 4.0 FINDINGS <br /> The results of the groundwater sampling indicate the following• <br /> • The groundwater gradient is consistent with past monitoring events The <br /> gradient indicates a eastern gradient direction with a slope of approximately <br /> 0 00006 inches per foot. Groundwater has dropped approximately four inches <br /> since the last monitoring event <br /> • Onlytwo monitoring events have been performed on the newly installed wells, <br /> i MW0-1,MWO-2,MWO-3 and MWO-1 X The three shallow borings MWO-1 <br /> through MWO-3 were non detect for MTBE indicating that the horizontal limits <br /> of MTBE in the shallow horizon have been defined. MW0-1X contained <br /> elevated detections of MTBE of 470 ppb, however, this was a decrease from the <br /> first monitoring event of 570 ppb in February 27, 2002. <br /> 1 <br /> 5.0 CONCLUSIONS <br /> Based on the above findings, Avalon concludes the following <br /> 1 Further groundwater monitoring will be necessary to determine if the decrease <br /> in the deep monitoring well MW0-1X in this quarter is representative of <br /> fluctuation or of a true decrease <br /> • Further groundwater monitoring will be necessary to determine if the offsite <br /> 1 property to the north which had a detection of MTBE in this quarter has been <br /> significancy impacted. <br /> 1 <br /> Avalon Environmental Consultants Project# 9627-001-11 <br /> Joes Truck Plaza 15600 South Harlan Road <br /> September 30, 2002 7 Lathrop, California <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.