Laserfiche WebLink
r <br /> 5.0 CONCLUSIONS <br /> 1 Based on the above findings, Avalon concludes the following <br /> • Further groundwater monitoring will be necessaryto determine if the decrease <br /> in the deep monitoring well MW0-1X in this quarter is representative of <br /> fluctuation or of a true decrease <br /> 1 <br /> 6.0 RECOMMENDATIONS <br /> Based on the above conclusion, Avalon recommends the following <br /> r This report should be forwarded to the Public Health Services San Joaquin <br /> County and the Regional Water Quality Control Board Central Valley Region <br /> (RWQCBCVR) for their review <br /> • Further groundwater testing should be performed prior to installation of any <br /> r new deep wells in order to determine if the contaminant levels encountered in <br /> MWO-1X are truly decreasing or if lust the levels encountered in the last two <br /> events are random fluctuation _ <br /> 7.0 ASSESSMENT LIMITATIONS <br /> r � <br /> The scope of this report is limited to the matters expressly covered This report is <br /> prepared forthe sole benefit of Washington Mutual Bank, and may not be relied upon <br /> by any other person or entity without the written authorization of Avalon <br /> i In preparing this report, Avalon has relied on information derived from secondary <br /> sources and personal interviews Except as set forth in this report, Avalon has made <br /> no independent investigation as to the accuracy and completeness of the information <br /> derived from secondary sources of personal interviews, and has assumed that such <br /> information is accurate and complete <br /> It should be recognized that the definition and evaluation of geologic and hydrologic <br /> conditions, as well as the assessment of chemical fate and movement in these <br /> conditions is a difficult and inexact science Judgments leading to conclusions are <br /> generally made with incomplete knowledge of the subsurface conditions present <br /> i More extensive studies maybe performed to reduce these inherent uncertainties No <br /> warranty, expressed or implied, is made <br /> All recommendations, findings, and conclusions stated in this report are based upon <br /> facts and circumstances as they existed at the time that this report was prepared (e g <br /> i federal, state and local laws, rules, regulations, market conditions, energy costs, wage <br /> Avalon Environmental Consultants Protect#9627-001-10 <br /> Joes Truck Plaza 15600 South Harlan Road <br /> August 19, 2002 7 Lathrop, California <br /> i <br />