T <br /> ® <br /> JOG'S Tr�Fc Plaza <br /> 15600 Harlan Road <br /> Lathrop, California <br /> DPE Test Summary using well MW-7 <br /> TE Applied Air Totalizer Vol of GW Cumul GW Influent Induced Vacuum("WC),DTW(feet bgs),&DD(feet)Data In Observation Wells <br /> Date&Time Vac Flow Reading Extracted Vol Ext Rate PID MW-1 MWO-iX MW-2 MW-3 <br /> hh mm "Hg cfm gallons gallons gallons gpm ppmir Vac I DTW DD Vac DTW I DD Vac DTW I DD Vac DTW DD <br /> 61161200410 00 4000 270 87 41,510 490 17,170 817 00 0 934 020 0 8 97 034 004 903 034 0 8 78 014 <br /> 61161200411 00 4100 275 87 42,000 490 17,660 817 00 0 935 021 0 9 00 0 37 004 900 031 0 8 78 014 <br /> 6116120041145 4145 NM NM 42,123 123 17,783 205 Discontinue test, DPE system hour meter=839 6 and DTW=917 feet bgs <br /> Average 258 870 -- -- 72 00 0 929 015 0 892 029 0 01 8 97 028 000 $73 009 <br /> Distance to Extraction well MW-7 80 30 30 102 <br /> Screening Interval 4- 19 5-20 20-30 5-20 5-20 <br /> Notes <br /> TE-Time Elapsed,hours minutes cfm-cubic feet per nunute <br /> Vac- Vacuum GW Ext-Groundwater Extraction <br /> DTW-depth to groundwater PID-Photo Ionization Detector <br /> "WC-Inches water column All induced vacuum measured in observation wells were in"WC <br /> ppmv-parts per million by volume Vol-Volume <br /> Temp-Temperature Cumul-Cumulative <br /> deg F-degree Farenheit gpm-gallons per minute <br /> Ext -Extraction "Hg- Inches Mercury <br /> DD- Drawdown bgs -below ground surface <br /> Joe's Truck DPE Test Tables Page 3 of 3 5R 7115 <br />