Laserfiche WebLink
r ------------------------------------------------------------------------------ <br /> FALLING HEAD PERMEABILITY TEST CONDITIONS DATA <br /> • CellNo. : 2F Panel No. : 2 <br /> r Positions: F <br /> Run Number: 1 2 <br /> Cell Pressure: 62 . 0 psi 0 . 0 psi <br /> Inflow Saturation Pressure: 60. 0 psi 0. 0 psi <br /> Inflow Buret Area: 0. 3000 cm2 0 . 3000 cm2 <br /> r Outflow Buret Area: 0. 3000 cm2 0 . 3000 cm2 <br /> Test Temperature: 20. 5 °C 0. 0 °C <br /> --------------- <br /> PERMEABILITY TEST READINGS DATA <br /> CASE DATE TIME ELAPSED INFLOW OUTFLOW OUTFLOW/ PERM. PERM / <br /> D X (24 hr) TIME LEVEL LEVEL INFLOW K RUNNING <br /> S sec cm cm RATIO cm/sec 4 AVE <br /> S X 1/26/ 1 12 : 10: 15 0 85. 10 7. 7 0 . 00 0 . 00E 00 0 . 00 <br /> R X 1/26/ 1 12 : 10 : 20 5 79 . 20 14 . 5 1 . 15 9 . 27E-04 0 . 00 <br /> X 1/26/ 1 12 : 10: 25 5 73 . 70 20. 8 1. 15 1. 04E-03 0 . 00 <br /> X 1/26/ 1 12 : 10: 30 5 68 . 70 25. 8 1. 00 1. 08E-03 0 . 00 <br /> 1/26/ 1 12 : 10 : 35 5 64 . 40 30. 0 0 . 98 1 . 14E-03 1 . 09 <br /> 1/26/ 1 12 : 10 : 40 5 60. 70 33 . 7 1. 00 1. 25E-03 1 . 11 <br /> 1/26/ 1 12 : 10: 45 5 57 . 80 36. 5 0. 97 1. 23E-03 1. 04 <br /> 1 1/26/ 1 12 : 10 : 50 5 55. 60 38. 7 1 . 00 1. 20E-03 0 . 99 <br /> Average differential head = 0. 3 psi, 23 . 2 cm H2O <br /> Gradient = 9 . 174E 00 Total vol = 9 . 08E 00 cc Test duration = 35 sec <br /> Permeability, K20. 50 = 1. 205E-03 cm/sec, K200 = 1. 190E-03 cm/sec <br /> Permeability values are incremental <br /> 1 <br /> 1 <br /> i <br /> • <br />( PAGE 2 SIERRA TESTING DATA SET 84 <br />