My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002630
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15600
>
3500 - Local Oversight Program
>
PR0545273
>
ARCHIVED REPORTS_XR0002630
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 6:25:35 PM
Creation date
2/3/2020 11:25:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002630
RECORD_ID
PR0545273
PE
3528
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
02
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S 4.0 FINDINGS <br /> The results of the groundwater sampling Indicate the following <br /> • The groundwater gradient is consistent with past monitoring event The <br /> gradient Indicates a northeast gradient direction with a slope of approximately <br /> 0 0005 Inches per foot Groundwater has dropped approximately two feet <br /> since the last monitoring event <br /> • MTBE levels are elevated northeast of the former tank pit area as opposed to the <br /> higher readings found in the previous monitoring event in monitoring well MW- <br /> 1 which is located within the former tank pit area <br /> I <br /> 5.0 CONCLUSIONS <br /> Based on the above findings, Avalon concludes the following <br /> • Further groundwater monitoring will be necessary to determine the most <br /> consistent gradient direction <br /> 6.0 RECOMMENDATIONS <br /> Based on the above conclusions, Avalon recommends the following <br /> • This report should be forwarded to the Public Health Services San Joaquin <br /> County and the Regional Water Quality Control Board Central Valley Region <br /> (RWQCBCVR) for their review <br /> I <br /> • Further characterization is necessary, both offsite and onsite in order to fully <br /> define the vertical and horizontal extent of groundwater impact <br /> 7.0 ASSESSMENT LIMITATIONS <br /> The scope of this report is limited to the matters expressly covered This report is <br /> prepared for the sole benefit of Washington Mutual Bank, and may not be relied upon <br /> by any other person or entity without the written authorization of Avalon <br /> i In preparing this report, Avalon has relied on information derived from secondary <br /> sources and personal interviews Except as set forth in this report, Avalon has made <br /> no independent investigation as to the accuracy and completeness of the information <br /> derived from secondary sources of personal interviews, and has assumed that such <br /> Information is accurate and complete <br /> i � <br /> ANDML <br /> Avalon Environmental Consultants Project#9627-001-4 <br /> Joes Truck Plaza 15600 South Harlan Road <br /> October 11, 2000 4 Lathrop, California <br />
The URL can be used to link to this page
Your browser does not support the video tag.