Laserfiche WebLink
GROUNDWATER MONITORING AND SAMPLING REPORT <br /> BP Oil Company Service Station,No. 11195 <br /> X6500 South Interstate I-5 <br /> Lathrop, California <br /> Project No. 10-151-03-002 <br /> March 9, 1995 <br /> INTRODUCTION <br /> This report presents the results and findings of the December 8, 1994 groundwater <br /> monitoring'and sampling conducted by Alisto Engineering Group at BP Oil Company Service <br /> Station No. 11195, 16500 South Interstate I-5, Lathrop, California. A site vicinity map is <br /> shown in Figure 1. <br /> FIELD PROCEDURES <br /> Field activities were performed in accordance with the procedures and guidelines of <br /> San Joaquin County Public Health Services and the California Regional Water Quality <br /> ' i Control Board, Central Valley Region. <br /> Before purging and sampling, the groundwater level in each well was measured from a <br /> permanent mark on top of the casing to the nearest 0.01 foot using an electronic sounder. <br /> The depth to groundwater and top of casing elevation data were used to calculate the <br /> groundwater elevation in each well. The survey data and groundwater elevation <br /> measurements collected to date are presented in Table 1. <br /> Before sample collection, each well was purged of 3. casing volumes, while recording field <br /> readings of pH, temperature, and electrical conductivity. Groundwater samples were <br /> collected for laboratory analysis by lowering a bottom-fill, disposable bailer to just below the <br /> water level in the well. The samples were Transferred from the bailer into laboratory- <br /> supplied containers. T6 water,sampling field survey forms are presented in Appendix A. <br /> SAMPLING AND ANALYTICAL RESULTS <br /> The results of monitoring and laboratory analysis of the groundwater samples for this and <br /> previous quarters are summarized in Table 1. The potentiometric groundwater elevations as <br /> interpreted from the results of this monitoring event are shown in Figure 2. The results of <br /> groundwater analysis are shown in Figure 3. The laboratory report and chain of custody <br /> record are presented in Appendix B. <br /> s 'i <br />