Second Quarter 2015 Site Status Report August 14, 2015
<br /> Former Nestle USA, Inc. Facility, Ripon, CA
<br /> o Eight Diamond Pet Food wells (PW-6, PW-8, TH-1, TH-7, TH-8, TH-9, TH-
<br /> 10, and TH-11),
<br /> o Four private irrigation wells (RPS-1, RC-2, CALTRANS, and 7507 Kiernan
<br /> Ave-Irr),
<br /> o One IRAP treatment system at 230 Industrial Avenue (influent, mid-point
<br /> and effluent),
<br /> o Three domestic well treatment systems (5725 Hall Road, 7501 Kiernan
<br /> Avenue, and 802 Vera Avenue), and
<br /> o Twelve domestic wells (110 Manley Road, 361 Parallel Avenue, 5500 Hall
<br /> Road, 5724 Hall Road, 7717 Kiernan Avenue, 7961 Kiernan Avenue, 7969
<br /> Kiernan Avenue, 7971 Kiernan Avenue, 8001 Kiernan Avenue, 8313
<br /> Kiernan Avenue, 1051 Robert Avenue, and RC-1)a.
<br /> ECM sent VOC samples to TestAmerica Laboratory in Pleasanton, California for analysis
<br /> using either United States Environmental Protection Agency (USEPA) Method 82608 or
<br /> USEPA Method 524.2, as required by MRP R5-2014-0815.
<br /> In addition, ECM collected the following MNA data in accordance with the Monitored
<br /> Natural Attenuation Work Plan (ECM, 2014):
<br /> • Between April 2 and June 18, 2015, ECM monitored and collected geochemical
<br /> samples from:
<br /> o Fifty-three (54) Nestle monitoring wells (13 Upper Aquifer wells, 30
<br /> Intermediate Aquifer wells, and 11 Lower Aquifer wells) using low-flow
<br /> purging techniques,
<br /> o Seventeen (17) Nestle monitoring wells (1 Upper Aquifer well, 15
<br /> Intermediate Aquifer wells, and 1 Lower Aquifer well) for compound-specific
<br /> isotope analysis (CSIA).
<br /> Geochemical samples were sent to TestAmerica Laboratory in Pleasanton, California and
<br /> analyzed for nitrate and sulfate (USEPA Method 300), sulfide (SM4500-S), ferrous iron
<br /> and dissolved manganese (USEPA Method 6010B), and methane (RSK-175). CSIA-
<br /> carbon samples were sent to Microseeps/Pace Analytical Energy services, LLC for
<br /> measurement of stable isotope ratios with an isotope-ratio mass spectrometer (IRMS).
<br /> Microseeps/Pace also analyzed VOCs (USEPA Method 8260B) for the 17 CSIA-carbon
<br /> samples.
<br /> Figure 2 through Figure 4 depict the potentiometric surface maps for the Upper,
<br /> Intermediate, and Lower aquifers. Table 1 through Table 4 present pertinent well
<br /> information, water level elevation, and water quality analytical data. Table 5 presents the
<br /> well purge parameters and laboratory results for geochemical analysis. Table 6
<br /> The well at 415 Parallel Avenue was not sampled because there was no access to the property. The
<br /> property has been condemned by the City of Ripon and ECM personnel confirmed the property was
<br /> unoccupied during the sampling period.
<br /> 2