Laserfiche WebLink
TABLE 1 <br /> REQUIRED MONITORING <br /> INDUSTRIAL AVENUE AND FUTURE REMEDIAL GROUNDWATER TREATMENT SYSTEMS <br /> Former Nestle USA, Inc. Facility <br /> EPA Analytical Quantitation <br /> Constituents Minimum Sampling Frequency b <br /> Method Limit <br /> Influent <br /> Volatile Organic Compoundsa Quarterly 8021 0.5 pg/L <br /> Mid-Point <br /> Volatile Organic Compounds' Quarterly 8021 0.5 pg/L <br /> Effluent <br /> Volatile Organic Compounds"' Quarterly 8021 0.5 pg/L <br /> pH, Temperature, Conductivity, and Total Twice per Month Calibrated Field Meter + 0.1 unit <br /> Dissolved Solids <br /> a Discharger must analyze and report full suite of VOCs. All estimated concentrations must be reported. <br /> b EPA methods yielding equivalent or lower method quantitation limits may also be used. <br /> c Discharger shall report all VOC detections in effluent to Regional Board staff within 24 hours of receipt of lab results. Discharger shall immediately shutdown the <br /> treatment plant if VOCs are detected in effluent samples at concentrations equal to or above Federal or State Maximum Contaminant Levels(MCLS). <br /> d For total dissolved solids use EPA 300 series method. <br /> Monitoring and Reporting Program No. R5-2014-0815 <br /> Nestle' USA, Inc. - Ripon, San Joaquin County <br /> Table 1 of 4 <br />