Monitoring Well Installation Report April 15, 2010 <br /> Former Nestle USA, Inc. Facility, Ripon, CA <br /> remediated the areas near new wells M-52B and M-5313, based on the low-level TCE <br /> concentrations observed in these new wells. <br /> 7.3 ANALYTICAL RESULTS FOR OFF-SITE WELL M-54C <br /> Monitoring well M-54C was sampled using PDB sampling technology on January 18, <br /> 2010. The analytical results are provided on Table 7 and the laboratory analytical report <br /> is provided in Appendix E. <br /> Groundwater in this area is locally affected by recharge and discharge areas, and <br /> generally flows away from recharge areas, including the City of Ripon municipal lagoons. <br /> In all four quarters of 2009, high groundwater elevations in the Intermediate Aquifer were <br /> observed due to mounding in the recharge area, affecting wells such as M-17C1 and M- <br /> 20C1, which are located north of the lagoons. As a result of the effects of this recharge <br /> area, groundwater flows to the north from the lagoons, towards the Stockton Avenue <br /> site. Therefore, it is expected that concentrations observed near the lagoons (M-17C1 <br /> and M-20C1) would have trend moving north and away from lagoons towards the <br /> Stockton Avenue site. <br /> Table 8 and Figure 9 provide a comparison of COC data for wells located in the vicinity <br /> of the Stockton Avenue site and the municipal lagoons. <br /> 8 CONCLUSIONS AND RECOMMENDATIONS <br /> The following conclusions and recommendations may be drawn from the data collected <br /> from the field activities associated with the installation of wells M-50A, M-51 A, M-5213, M- <br /> 53B, and M-54C: <br /> INDUSTRIAL AVENUE SYSTEM <br /> • The purpose of installing two groundwater monitoring wells within the A Zone at <br /> the 230 Industrial Avenue site was to evaluate the eastern and western extents <br /> of the capture zone of the Industrial Avenue IRAP Treatment System wells EU-3 <br /> and EU-4. In order to conduct the proposed capture zone analysis, a temporary <br /> shutdown of the system will be necessary to collect static water level data in the <br /> vicinity of the system. Details of the proposed system shutdown, monitoring and <br /> sampling during the shutdown, and post-shutdown monitoring, will be <br /> documented under separate cover <br /> The discrete groundwater samples collected from wells M-50A and M-51A <br /> indicate the presence of low levels of TCE within the area of influence of the <br /> Industrial Avenue IRAP Treatment System. Groundwater samples collected from <br /> borings advanced in 2005 and 2007 exhibited much higher TCE concentrations, <br /> as illustrated in Table 4. The reduction in localized TCE concentrations indicates <br /> that the Industrial Avenue IRAP Treatment System is operating efficiently and <br /> has been successful in removing COC mass from the area targeted by the <br /> treatment system. <br /> Stockton Avenue System <br /> • The purpose of installing two groundwater monitoring wells within the within the B <br /> Zone beneath the Stockton Avenue site was to determine if concentrations of <br /> 9 <br />