Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike PO Box 12425 Lancasler PA 17605-2425•717-656 2300 Fax 717-656-2681•www lancaster labs com <br /> Page l of 2 <br /> Lancaster Laboratories Sample No WW 4177758 <br /> MW-47A-W-031203 Grab Water <br /> Facility# 1001621 Job# 386883 GRD <br /> 22888 Kassen Rd Banta T0607700004 MW-47A <br /> Collected 12/03/2003 14 40 by TC Account Number 10906 <br /> Submitted 12/05/2003 09 15 ChevronTexaco <br /> Reported 12/23/2003 at 14 18 6001 Bollinger Canyon Rd L4310 <br /> Discard 01/23/2004 San Ramon CA 94583 <br /> MW47A <br /> As Received <br /> CAT As Received Method Dilution <br /> No Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 01728 TPH-GRD - Waters n a 2,000 500 ug/1 10 <br /> The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time <br /> A site-specific MSD sample was not submitted for the project A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level <br /> 05553 TPH - DRO CA LUFT (Waters) n a 670 50 ug/l 1 <br /> According to the California LUFT Protocol the quantitation for Diesel <br /> Range Organics was performed by peak area comparison of the sample pattern <br /> to that of our 42 fuel oil reference standard (between C10 and C28 normal <br /> hydrocarbons) <br /> . Site-specific MS/MSD samples were not submitted for the project A LCS/LCSD <br /> was performed to demonstrate precision and accuracy at a batch level <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct Injection) 67-56-1 N D 200 ug/l 1 <br /> 06059 BTEX+5 Oxygenates+ETON <br /> 01587 Ethanol 64-17-5 N D 250 ug/l 5 <br /> 02010 Methyl Tertiary Butyl Ether 1634-04-4 3,300 25 ug/l 50 <br /> 02011 di-Isopropyl ether 108-20-3 N D 3 ug/1 5 <br /> 02013 Ethyl t-butyl ether 637-92-3 N D 3 ug/1 5 <br /> 02014 t-Amyl methyl ether 994-05-8 1,400 25 ug/l 50 <br /> 02015 t-Butyl alcohol 75-65-0 N D 25 ug/l 5 <br /> 05401 Benzene 71-43-2 N D 3 ug/1 5 <br /> 05407 Toluene 108-88-3 N D 3 ug/l 5 <br /> 05415 Ethylbenzene 100-41-4 N D 3 ug/1 5 <br /> 06310 Xylene {Total) 1330-20-7 N D 3 ug/l 5 <br /> The reporting limits for the GC/MS volatile compounds were raised <br /> because sample dilution was necessary to bring target compounds into the <br /> calibration range of the system <br /> State of California Lab Certification No 2116 <br /> Laboratory Chronicle <br /> CAT Analysis Dilution <br /> 0110 Analysis Name Method Trial# Date and Time Analyst Factor <br />