Vicki McCartney, REHS Treci '&Rdb <br /> 20 January 2005 <br /> Page 2 MEMORANDUM <br /> from the shallow zone at approximately 30-feet bgs and deep zone at approximately <br /> 60 feet bgs . Temporary PVC casing will be used to collect shallow zone <br /> groundwater, and a Hydropunch will be used to collect deep zone groundwater. <br /> 2. Soil samples will be retained every 5-feet from 50 to 70 feet, or at lithologic changes <br /> for possible laboratory analysis . Due to the low yield clays previously encountered in <br /> the deep groundwater zone, boring casing may be left in place overnight if no <br /> groundwater is recovered the first day. Open borings will be protected to prevent <br /> intrusion of water and covered with steel plates to restrict access . Cones and/or <br /> barricades will be used over the borings. <br /> Laboratory Analyses <br /> 1 . Groundwater samples will be analyzed for TPHg, BTEX, fuel oxygenates, 1 ,2-DCA, <br /> and EDB , using EPA method 826013 , and TPH as kerosene (TPHk) by EPA Method <br /> 8015M with a silica gel cleanup. <br /> 2. Soil samples will be analyzed for TPHg, and BTEX and MTBE by EPA Method <br /> 8015M and EPA Method 8021 , and TPHk by EPA Method 8015M with a silica gel <br /> cleanup. <br /> Please contact us with any questions or comments . <br /> VAHmme\DUSTYNE\SF ProjectAStockton Garage\WP Addendum for Jan 25.doc ' <br />