My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JAHANT
>
6787
>
3000 – Underground Injection Control Program
>
PR0518315
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 5:42:51 PM
Creation date
2/5/2020 4:22:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3000 – Underground Injection Control Program
File Section
WORK PLANS
RECORD_ID
PR0518315
PE
3030
FACILITY_ID
FA0013829
FACILITY_NAME
KOOYMAN DAIRY/ LAB CLEAN UP
STREET_NUMBER
6787
Direction
E
STREET_NAME
JAHANT
STREET_TYPE
RD
City
ACAMPO
Zip
95220
CURRENT_STATUS
02
SITE_LOCATION
6787 E JAHANT RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9-1110.1 <br /> i <br /> CHAPTER 9-1110 Sanitation Permit shall include a site plan which clearly <br /> delineates the location and characteristics of the proposed <br /> PRIVATE ON-SITE WASTEWATER DISPOSAL use. <br /> FACILITIES REGULATIONS (b) Review Procedures. Sanitation Permit applica- <br /> tions shall be reviewed by the Director of the Environ- <br /> Sections: mental Health Division using the Staff Review Procedure <br /> 9-1110.1 Intent. in Chapter 9-210, with the following modifications: <br /> 9-1110.2 Public Sanitary Sewer (1) Preapplication Conferences shall not be <br /> Connections Required. required; and <br /> 9-1110.3 Sanitation Permit Required. (2) The time limit for approval shall be one(1) <br /> 9.1110.4 Sanitation Permit Requirements,, year. - <br /> 9-1110.5 Private On-Site Wastewater (c) Development Requirements.Sanitation Permits <br /> Disposal Facilities Standards. approved under the provisions of this Chapter shall be <br /> 9-1110.6 Prohibited Uses. subject to those conditions which ensure that the'pro- <br /> 9-1110.7 Prohibited Discharges. posed use meets the minimum requirements of the Coun- <br /> 9-1110.8 Septic Tank Pumping. ty including, but not limited to, the following means or <br /> 9-1110.9 Compliance Required. proposed means for the disposal,treatment,or discharge <br /> 9-1110.10 Violations. of wastewater: <br /> 9.1110.11 Right to Appeal. (1) Will not permit the escape of any unpleas- <br /> 9-1110.12 Environmental Health Division ant or noxious odors, vapors, or gases; <br /> Fees and Fines. (2) Will not permit the ingress and egress of <br /> flies, other insects, rodents, or animals; <br /> 9-1110.1 INTENT. (3) Will not permit the discharge of wastewater <br /> 1 The intent of this Chapter is to specify the minimum! or the discharge or drainage of effluent from the <br /> regulations for the use of private,on-site wastewater dis-; wastewater disposal system to empty, flow, seep, drain, <br /> posal facilities. condense into, or otherwise pollute any watercourse, or <br /> e <br /> (Ord. 3675) J other waters used or which may be used or suitable for <br /> use for domestic, recreational, or agricultural purposes; <br /> 9-1110.2 PUBLIC SANITARY SEWER (4) Shall not be offensive,dangerous,or injuri- <br /> CONNECTIONS REQUIRED. ous to health, or create a nuisance; and <br /> Private,on-site wastewater disposal facilities shall not (5) Shall conform in all respects to the regula- <br /> be approved where public wastewater collection and; tions and standards of the Environmental Health Division <br /> disposal are required pursuant to Chapter 9-1105. for the disposal, treatment, or discharge of sewage. <br /> (Ord. 3675) (d) Inspection of Permitted Work. Work done ' <br />! under any Sanitation Permit shall not be covered, con- <br /> 9-1110.3 SANITATION PERMIT REQUIRED.,; cealed, or put into use until it has been inspected and <br /> It shall be unlawful for any person to construct, add. approved by the Director of the Environmental Health <br /> to, modify, or alter any vaulted privy, septic tank; Division. J <br /> wastewater disposal system, other pipe or conduit, of (e) Changes May Be Ordered.The Director of the <br /> other means for the disposal, treatment, or discharge of Environmental Health Division may order changes to any <br /> wastewater without first securing a Sanitation Permit existing system,method,means,manner,or place for the <br /> from the Director of Environmental Health. disposal, treatment, or discharge of sewage in order that <br /> (Ord. 3675) they shall not constitute a menace to the health of human <br /> beings or animals. The orders of the Director of the <br /> 9-1110.4 SANITATION PERMIT Environmental Health Division shall designate the period <br /> REQUIREMENTS. within which such changes are to be made. <br /> Sanitation Permits shall be subject to the following (f) Special Permits. Notwithstanding any other <br /> requirements: provisions of this Chapter,the Director of Environmental <br /> (a) Requirements for Application.Applications for Health may approve Special Permits for limited periods <br /> Sanitation Permits may be initiated b the property owner of time when the requirements of this Chapter or any of <br /> Y Y p Pe <br /> or his/her authorized agent. Applications shall be filed the standards adopted pursuant to this Chapter are found <br /> with the Environmental Health Division. A request for a to be impracticable or unnecessary. In approving a Spe- <br /> I <br /> 536 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.