Laserfiche WebLink
CALIFORNIA LABORA TOR Y SER VICES <br /> 11/21/03 14 05 <br /> EEC Project Stockton Uniftrst CLS Work Order# CMKOtS55 <br /> 501 Parkcenter Drive Project Number 51462-1 <br /> Santa Ana,CA 92705 Project Manager Dave Bernier COC# 43322 <br /> Notes and Definitions <br /> t—AS-1 Although sample contains compounds in the retention time range associated with gasoline,the chromatogram was not consistent <br /> with the expected chromatographic pattern or"fingerprint" However,the reported concentration is based on gasoline <br /> �M-05 The spike recovery was outside acceptance limits for the MS and/or MSD due to matrix interference The LCS and/or LCSD were <br /> within acceptance limits showing that the laboratory is in control and the data is acceptable <br /> QM-07 The spike recovery was outside acceptance limits for the MS and/or MSD The batch was accepted based on acceptable <br /> LCS/LCSD recovery <br /> tR-02 The RPD result exceeded the QC control limits,however,both percent recoveries were acceptable Sample results for the QC <br /> batch were accepted based on percent recoveries and completeness of QC data <br /> 104 The surrogate recovery for this sample is outside of established control limits due to a sample matrix effect <br /> ET Analyte DETECTED <br /> ID Analyte NOT DETECTED at or above the reporting limit <br /> R Not Reported <br /> Sample results reported on a dry weight basis <br /> Relative Percent Difference <br /> 1 <br /> 1 <br />