Laserfiche WebLink
MONITORING AND REPORTING ORDE#. R5-2015-0808 • -5- <br /> DEUEL VOCATIONAL INSTITUTION <br /> 23500 KASSON ROAD,TRACY <br /> 6. As required by the California Business and Professions Code sections 6735, 7835, <br /> and 7835.1, all reports shall be prepared by a registered professional Civil Engineer <br /> or Geologist or their subordinate and shall be signed by the registered professional. <br /> 7. Semi-annual electronic reports, which conform to the requirements of the California <br /> Code of Regulations, Title 23, Division 3, Chapter 30, shall be submitted <br /> electronically over the internet to the State Water Resources Control Board <br /> Geotracker database system by 1 August and 1 February, or as otherwise <br /> indicated by Central Valley Water Board staff, until such time as the Executive <br /> Officer determines that the reports are no longer necessary. Each report shall <br /> include the following minimum information: <br /> (a) A description and discussion of the groundwater sampling event and results, <br /> including trends in the concentrations of pollutants and groundwater <br /> elevations in the wells, how and when samples were collected, and whether <br /> the pollutant plume(s) is delineated. <br /> (b) Field logs that contain, at a minimum, water quality parameters measured <br /> before, during, and after purging, method of purging, depth of water, volume <br /> of water purged, etc. <br /> (c) Groundwater contour maps for all groundwater zones, if applicable. <br /> (d) Isocontour pollutant concentration maps for all groundwater zones and all <br /> major constituents of concern, if applicable. <br /> (e) A table showing well construction details such as well number, groundwater <br /> zone being monitored, coordinates (longitude and latitude), ground surface <br /> elevation, reference elevation, elevation of screen, elevation of seal, elevation <br /> of filter pack, and elevation of well bottom. <br /> (f) A table showing historical lateral and vertical (if applicable) flow directions and <br /> gradients. <br /> (g) Cumulative data tables for all major constituents of concern containing the <br /> water quality analytical results and depth to groundwater for all monitoring <br /> wells for at least the past five years, if applicable. Older data may also be <br /> provided. The Central Valley Water Board may request additional data as <br /> necessary. <br /> (h) A copy of the laboratory analytical data report. <br /> (i) If applicable, the status of any ongoing remediation, including cumulative <br /> information on the mass of pollutant removed from the subsurface, system <br /> operating time, the effectiveness of the remediation system, and any field <br /> notes pertaining to the operation and maintenance of the system. <br />