My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 3:35:59 PM
Creation date
2/6/2020 8:58:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
574
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County IV E: D <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 0 C T U 3 2016 <br /> Telephone.(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> lJnclar'giRou'rrd Surae Tann Progratt I,nspron HEA TH <br /> Facility Name: Facility Address: Date: <br /> 99 SHELL* 7700 MORELAND ST, STOCKTON August 24, 2016 <br /> ti. <br /> L15TS}(WIn <br /> F , , <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V o R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V o R o COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V a R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ti V ❑R o COS <br /> 328 HSC 25298 Failed to comply v4ith temporary clmswa requireme9ts o V e R n COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements V o R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system 17V o R o COS <br /> � �;� " � `� Natl�Piresiaur�e:�ipi itt <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve fj V io R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V v R a COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) a V o R COS <br /> 404 xCCR 2643(e) Biennial 0.1 gph test for gravity piping not <br /> performed(pre-January 1984) ❑V o R ❑COS <br /> 2010 See below Unlisted Administration/Documentation violation o V n R o COS <br /> 2030 See below Unlisted Operabons/ilnaintenanoe violation o V o R C,COS <br /> 2060 See below Unlisted Design/Construction violation ❑V R e COS <br /> `' :,'` .�UMr1AARl�QF V�C�tAfiflt7H$ , r <br /> „(Ct 14551, <br /> 'L*!i;or Iy11NOR:Nati e'to Campiy) c <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted, <br /> Financial responsibility documents have not been submi to :, Environmental Reporting System (CERS). <br /> Current financial responsibility documents are red urs c: '_� Ll; tjbmiit-�Ld 3nnuaily. Immediately log into CERS at i <br /> http://cers.calepa.ca.gov/, and upload the required c 4-c:.rnlents. <br /> This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(1)Failed to have an approved UST monitoring plan. <br /> The underground storage tank(UST) monitoring plan for tank TA0515772 is incomplete. Beneath Under Dispenser <br /> Containment(UDC) Monitoring, complete UDC construction by entering Double-walled,complete UDC Secondary <br /> Containment Monitoring by entering Liquid, and comp4ete Leak Within Secondary Containment of UDC Causes <br /> Audible and Visua Alarms by entering"yes" <br /> The UST monit,iring planjor tank TA0515774 is incorrc,01.. Recordkeeping, change"No"'to"yes"for <br /> Equipment Maintenance and Calibration Records. Immediately log into California Environmental Reporting System <br /> (CEfZS)at http://cers.calepa.ca.gov/,and revise the required documents. <br /> This is a repeat violation, Class IL <br /> Page 3 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.