TRAFFIC RATED WELL COVER <br /> "Note:3 FEET OF 1/4"TEFLON TUBING WILL BE <br /> ABOVE GROUND SURFACE(Not illustrated) <br /> SURFACE GRADE <br /> 1/4"TEFLON TUBING <br /> 3 FEET asg(above surface grade)-5 1/2 FEET bsg <br /> NEAT CEMENT SEAL(BENTONITE 1-5%),1/2-4 112 FEET bsg <br /> 1 <br /> DRY BENTONITE CHIP SEAL,4 112-5 FEET bsg <br /> VAPOR PROBE FILTER PACK(#2/12 SAND)5-6 1/2 FEET bsg <br /> 5 1/2-6 FEET bsg <br /> I� <br /> A-BOREHOLE DIAMETER <br /> ALL DEPTHS RELATIVE TO SURFACE GRADE <br /> NOT TO SCALE <br /> PROPOSED SOIL-VAPOR WELL Advanced <br /> RMB GARAGE GeoEnvironmental, Inc. <br /> www.advgeoenv.com <br /> 715 NORTH HUNTER STREET PROJECTNO. AGE-NC-01-0877 FILE SMELL FIGURE <br /> STOCKTON, CALIFORNIA DATE: JANUARY207 DRAWN BY:MAC 6 <br />