Laserfiche WebLink
TA E 9 <br /> SUMMARY OF VAPOR EXTRACTION SYSTEM ANALYTICAL DATA <br /> Farmer Property,610 Hunter Street, Stockton, CA <br /> Page 1 of 1 <br /> April 7 -June 29, 2005 <br /> Analyte Concentration u IL Volume Discharged (gallons) Liters/gallon Kq/uq K /ulbsIK9 lbs removed <br /> TPHg 180 87023 3 785 0000000001 2205 0 131 <br /> Benzene 3 375 87023 3 785 0000000001 2205 0 002 <br /> Toluene 3 375 87023 3 785 0000000001 2205 0 002 <br /> Eth (benzene 6 125 87023 3 785 0 000000001 2205 0 004 <br /> Xylenes 31 1 87023 3 785 0 0000000011 2205 1 0 023 <br /> MTBE 0 5 87023 3 785 1 0 0000000011 2205 1 0 000 <br /> Notes <br /> ug/L denotes micrograms per liter <br /> Concentration is the average influent concentration in ug/L based on laboratory analytical data <br /> provided in Table 5 <br /> Volume discharged in gallons based on calculated volume provided in Table 5 <br /> Where the effluent concentration was not detected at method detection limits, the detection limit <br /> was used in the calculation <br /> Conversions <br /> 3 785 liters per gallon <br /> 0 000000001 kilograms per microgram <br /> 2 205 pounds per kilogram <br />