My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0003267
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
3500 - Local Oversight Program
>
PR0545287
>
ARCHIVED REPORTS_XR0003267
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 4:28:23 PM
Creation date
2/6/2020 11:57:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0003267
RECORD_ID
PR0545287
PE
3528
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
02
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
placed on the sample in such a way that any attempt to tamper with the sample is easily <br /> visible <br /> A-2 4 Collection of BAT Probe Groundwater Samples <br /> I <br /> One-time groundwater samples are collected using a BAT Probe, which is an insitu <br /> groundwater sampling device The borings are first advanced to a point immediately above the <br /> desired sampling depth where groundwater is encountered A stainless steel drive tip equipped <br /> with a stainless steel filter is lowered into the boring at the end of a 2 5-inch diameter <br /> galvanized steel pipe and pushed using the drill rig approximately 6 to 12 inches into the <br /> soil/aquifer formation at the bottom of the boring A sterilized, glass, vacuum sealed sampling <br /> ampoule (tube), similar to a standard volatile organics (VOA) vial, is then lowered through the <br /> pipe down to the tip with a cable. Between the tip and the sample tube is a double-sided <br /> hypodermic needle (syringe), which simultaneously punctures the seals on the stainless steel <br /> drive tip and the septum of the glass sample ampoule. The vacuum in the sample ampoule <br /> draws groundwater through the tip into the glass ampoule. The glass ampoule is then pulled <br /> out of the pipe, disengaging the syringe The septum in the glass ampoule and drive tip reseals <br /> after the syringe is removed <br /> To reduce the potential of introducing contaminants into the samples, the drive tip, galvanized <br /> pipe, and other equipment used for sample collection are steam cleaned and/or washed with <br /> trisodium phosphate (TSP) solution and rinsed with distilled water prior to use The sample <br /> probe and filters are cleaned in TSP solution and rinsed with methyl alcohol followed by a <br /> distilled water rinse prior to use New, factory-sterilized syringe needles, 0-rings, septums <br /> and sample tubes are used for each sample <br /> A-2 5 Sample Handling <br /> After labeling, the sample is immediately stored in an iced cooler for transport to Kleinfelder`s <br /> office sample control or to the analytical laboratory A Kleinfelder chain-of-custody form <br /> accompanies the cooler The chain-of-custody form includes Kleinfelder's name, address and <br /> telephone number, the employee number of the individual who performed the sampling, the <br /> sample numbers, the date and time the samples were collected, the number of containers each <br /> sample occupies, and the analyses for which the samples are being submitted, if any The <br /> chain-of-custody form is signed by each person who handles the samples, including all <br /> Kleinfelder employees and the receiving employee of office sample control or the analytical <br /> laboratory when the samples are delivered <br /> A-2 6 Decontamination of Equipment <br /> To reduce the potential for cross-contamination, augers and associated equipment are steam <br /> cleaned prior to drilling each boring In addition, sampling equipment is cleaned with a <br /> tnsodium-phosphate wash and rinsed with distilled water prior to collecting each soil sample <br /> A-2 7 Soil Cutting Disposal <br /> Drill cuttings will be placed in 55-gallon drums or wrapped in plastic and left on site for <br /> disposal by the site owner If requested, Kleinfelder can coordinate disposal of soil and water <br /> after analytical results are available <br /> SAPROTO(1993) Page A-2 24-160241-000 <br /> Copyright 1993 Kleinfelder, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.