Site History <br /> Boyett Petroleum(419 S.Main St.,Manteca) <br /> Page 3 of 12 <br /> On September 30, 2002, Condor representatives surveyed the locations and elevations of MW-1 through <br /> MW-9. The well collars of the monitoring wells were surveyed relative to an established benchmark to <br /> comply with California Assembly Bill 2886. The survey data were collected with a Trimble 5700 <br /> Centimeter-Level RTK Global Positioning System(GPS) and referenced to the North American Datum of <br /> 1983 (NAD83). <br /> On November 20, 2002, Condor conducted a sensitive receptor survey (SRS) within a 2,000-foot radius <br /> of the site to identify potential areas of groundwater recharge or discharge, schools, and potential water <br /> well users that could be impacted by migration of groundwater from the site. The findings of the SRS <br /> included: <br /> Eighteen California Department of Water Resources (DWR) Central District well records <br /> pertained to 23 wells that were verified to be within the study area. <br /> During the area reconnaissance, Condor was unable to locate 20 of the 23 wells indicated by <br /> DWR well records. <br /> Of these 20 wells, 14 were classified as monitoring wells, four were classified as extraction wells, <br /> one was listed as an irrigation well, and one was indicated as "other". According to a Pacific Gas <br /> and Electric Company (PG&E) representative, PG&E is the owner of the well designated as <br /> "other". <br /> Of the three remaining wells, one well was destroyed (as documented by the DWR), and two <br /> monitoring wells (indicated on a single well record)were identified. <br /> A well record for a property located at 151 S. Main Street indicated that two monitoring wells <br /> were installed in 1996. These wells are part of a group of monitor and extraction wells that were <br /> not visible during Condor's area reconnaissance. The two monitoring wells are located <br /> approximately 1,000 feet north of the site. <br /> Four well locations not included in the information provided by the DWR were identified during <br /> the area reconnaissance. These included: <br /> A municipal well located at 323 (331) Jessie Avenue, approximately 1,500 feet west of <br /> the site. <br /> Nine monitoring wells located on-site at 419 S. Main Street, including the one located <br /> across Wetmore Avenue. <br /> Five monitoring wells located at 151 S. Main Street, approximately 1,000 feet north of <br /> the site. <br /> One drinking water well located at Manteca High School, approximately 1,800 feet <br /> northeast of the site. <br /> Two schools were identified within the study area: <br /> Manteca High School located at 450 E. Yosemite Avenue, approximately 1,400 feet <br /> northeast of the site. <br /> Manteca Community Day School located at 680 Mikesell Avenue, approximately 1,600 <br /> feet east of the site. <br /> ('limp xiratar mall the P;tv of MnintPra AXIa11 >iS limo nl vP rPA a* '212 7PcciP AlIPn11P <br /> approximately 1,500 feet west of the site. Mr. Eric Medeiros of CMPW described this well as <br />�� installed in 1952 to a total depth of 125 feet bgs and was constructed using 100 feet of 18-inch <br />