Laserfiche WebLink
ISAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street,Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.or <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> qq sN11 tAv, fytrLV Q1kV bIliIof <br /> Facility address: UST# I b I <br /> �1�IUuVWV44nd U-1 -Product <br /> Facility&A10 JO r <br /> Contact: Title: Phone: <br /> o�niitorin Panel: Piping system: O erfill prevention: <br /> ❑Pressurized El Suction ❑Gravitv fir M Mechanical ❑Audible/visual <br /> Ipec <br /> tion type:: J El <br /> Both <br /> Routine (J Monitoring Certification ❑Installation Other: 4M1-RDetect ❑M2-RPrev ( -3 <br /> VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> _T# <br /> Code Section V <br /> V=Violation; RV=R eat Violation <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b & c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 b Monitoring Pro (Monitoring&Response Plan is current and approved by the local agency. <br /> 6 CCR 2712 i) Monitoring plan is onsite. <br /> 7 CCR 2712 Maintenance&monitoring records (M 1) <br /> 8 CCR 2643 d Daily monitoring of suction piping(pre-January, 1, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present (M1) <br /> 11 CCR 2630 d UST system monitoring equipment is properly located to detect a leak (Mi) <br /> 12 HSC 25291 UST system monitoring equipment is operational (M2) <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping&UDC is present (M 1) <br /> 14 CCR 2631 a) Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detector(s) are installed (M 1) <br /> 18 CCR 2635(b)(1) Spill container (M2) <br /> 19 CCR 2635(b)(2) Overfill prevention system (M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoriN&20 containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases (M 1) <br /> 23 CCR 2715 Designated tor: a Statement from UST owner,F-1-Wonthly F-1-Monthlyinspection; f)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638 a Annual line leak detector test (M 1) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test (M 1) <br /> 28 CCR 2661 f) Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 a Biennial tightness test of gravity piping(pre-January 1, 1984 <br /> 30 CCR 2643 d) Triennial line test for conventional suction piping(pre-Janu 1, 1984) (M 1) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 b) Permit to temporarily close UST system <br /> 35 1 HSC 25298 c Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a Illegal abandonment of UST system <br /> 38 Other: <br /> EHD INSPECTOR: PHONE: UIC <br /> v�� S_pe tic system: <br /> q 9 Serves>_20 people/day <br /> R CEIVED Y: TITLE: —Receives other than sanitary waste <br /> Other disposal methods: <br /> —,, —Dry wells/French Drains <br /> EHD 23-02-002 REV 05/07 <br />