Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468.3433 Web:www.sigov.orglehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Nemo Express Market Addrees: 419 S Main Street, Manteca paw May 15, 2014 <br /> Facility b Kufjit Mangat Title: Phone:Pno e: 239-7978 <br /> Inspection XRouline XMonttodng System Certification fl Installation DComplaint—IDI/: 0Other. <br /> Type: <br /> (Authority HSC 5289) <br /> nspec Anita Na ier Cashier <br /> Consent(or. Xinspectlon 11 Sampling XPhetos Granted by: p Tllle: <br /> Monitoring Piping XPressurized (ISuction OGravily Over811 $Mechanicel [1 AudibleN(sual <br /> Panel; Veeder-Root TLS-350 System: Prevention <br /> usT 1 <br /> - 2 3 _____________ <br /> - ------ --nine --- - - -- -- - - -- - -- ------------ <br /> ------------ <br /> Product 67 91-octane DSL <br /> rator. Ron Rocha Dale:Designated Icc <br /> Ex <br /> Dpsi <br /> P. B715 Violations: XM1-Release Detection DM2-Release Prevention CM3—Both <br /> On 51teservice ICCExp. Meo0faclurersvR: 6-25-14, VMI: 11-12-15, TT:5-31-14 <br /> Tachnician: Felix Ramirez Date: 12-6-14 Training: <br /> VIOLATIONS <br /> S C1 C2 M I Code Sectio❑ HSC=Californls Hoallh and Safe( Cade;CCfl=Calilornia Cod of Re ulalions <br /> C1=Class 1 violation',C2=Class 2 violaeonl M=Minor violation <br /> .. -'file Review <br /> 101 HSC 25284 No permll to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that lire operating permit was Issued to and the tank operator to <br /> monitor the tank system <br /> 104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 X JCCR 2711 Current United Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 X CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot planlsiter map not submitted or falls to completely show where monitoring Is performed <br /> 108 CCR 2637 Secondary containment:(a)lest not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not Provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test nofifica8on not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(1) Annual line teak detector test not performed (M7) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(t)(4) Annual line lightness test not performed if positive shutdown or fall safe not present (Mt) <br /> 113 CCR 2715(a) Failed to Inform the EHD of a change of designated operator within 30 days _ <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification _ <br /> 115 CCR 2660(k) Repair for tank or piping not tested for lightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,of <br /> failures not repaired and retested <br /> 117 CCR 2881 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> „ On Site Records <br /> Maintenance&monitoring records riot maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 X CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or In the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 27121) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 OCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector. Received W. Till.: <br /> Garrett Backus (209) 468-2986 <br /> EHD 23-02 R"04119112 Page 1 UST INSPECTION REPORT <br /> I <br />