Laserfiche WebLink
1 <br /> t <br /> ANAMETRIX REPORT DESCRIPTION <br /> ' GC <br /> Organic Analysis Data Sheets (OARS) <br /> DADS forms contain tabulated results for target compounds The GADS are grouped by method and, within each <br /> method, organized sequentially in order of increasing Anametrix ID number <br /> Surrogate Recovery Summary (SRS) <br /> ' SRS forms contain quality assurance data An SRS form will be printed for each method, if the method requires <br /> surrogate compounds They will last surrogate percent recoveries for all samples and any method blanks Any <br /> surrogate recovery outside the established limits will be flagged with an "*", and the total number of <br /> surrogates outside the limits will be listed in the column labelled "Total Out" <br /> ' Matrix Spike Recovery Form (MSR) <br /> MSR forms contain quality assurance data They summarize percent recovery and relative percent difference <br /> information for matrix spikes and matrix spike duplicates This information is a statement of both accuracy <br /> and precision Any percent recovery or relative percent difference outside established limits will be flagged <br /> with an "*", and the total number outside the limits will be listed at the bottom of the page Not all reports <br /> will contain an MSR form <br /> Qualifiers <br /> Anametrix uses several data qualifiers (Q) in it's report forms These qualifiers give additional information <br /> on the compounds reported They should help a data reviewer to verify the integrity of the analytical results <br /> The following is a list of qualifiers and their meanings <br /> U Indicates that the compound was analyzed for, but was not detected at or above the specified reporting <br /> limit <br /> rB - Indicates that the compound was detected in the associated method blank <br /> J - Indicates that the compound was detected at an amount below the specified reporting limit <br /> Consequently, the amount should be considered an approximate value Tentatively identified compounds <br /> - will always have a "J" qualifier because they are not included in the instrument calibration <br /> E Indicates that the amount reported exceeded the linear range of the instrument calibration <br />' D - Indicates that the compound was detected to an analysis performed at a secondary dilution <br /> Absence of a qualifier indicates that the compound was detected at a concentration at or above the specified <br /> reporting limit <br />' REPORTING CONVENTIONS <br />' ♦ Due to a size limitation to our data processing step, only the first eight (8) characters of your project <br /> ID and sample TO will be printed on the report forms However, the report cover letter and report summary <br /> pages display up to twenty (20) characters of your project and sample IDs <br /> Amounts reported are gross values, e , not corrected for method blank contamination <br /> rmh/3426 - plsk iakH <br /> r <br />