Laserfiche WebLink
k'" KLEINFELDER <br /> sample ampoule The vacuum in the sample ampoule draws groundwater through the tip Into the <br /> glass ampoule The glass ampoule is then pulled out of the pipe, disengaging the syringe The <br /> 1 septum in the glass ampoule and drive tip reseals after the syringe is removed <br /> To reduce the potential for intioducing contaminants into the samples, the diive tip, galvanized <br /> pipe, and other equipment used for sample collection are steam cleaned and/or washed with <br /> trisodium phosphate or non-phosphate detergent solution and double rinsed with distilled water <br /> prior to use The sample probe and filters are cleaned in TSP solution and rinsed with methyl <br /> alcohol followed by a distilled water rinse prior to use New, factory-sterilized syringe needles, <br /> O-rings, septums and sample tubes are used for each sample <br />' A-2 6 Sample Handling <br /> After labeling, the sample is immediately stored in an iced cooler for transport to Kleinfelder's <br /> office sample control or to the analytical laboratory A Klemfelder chain-of-custody form <br /> accompanies the cooler The chain-of-custody form includes Kleinfelder's name, address and <br />' telephone number, the employee number of the individual who performed the sampling, the <br /> sample numbers, the date and time the samples were collected, the number of containers each <br /> sample occupies, the sample matrix (soil or water) and the analyses for which the samples are <br /> being submitted, if any The chain-of-custody form is signed by each person who handles the <br /> samples, including all Klemfelder employees and the receiving employee of office sample <br /> control or the analytical laboratory when the samples are delivered <br /> A-2 7 Decontamination of Equipment <br /> To reduce the potential for cross-contamination, augers and associated equipment are steam <br /> cleaned pnor to drilling each boring In addition, sampling equipment is cleaned with a <br /> trisodium phosphate or non-phosphate detergent wash and rinsed with distilled water prior to <br /> collecting each soil sample <br /> A-2 8 Soil Boring Closure and Cutting Disposal <br /> Soil borings are closed immediately after the collection and logging of soil samples Closure is <br /> accomplished by grouting the boring with a cement/bentonite slurry or as otherwise required <br /> I Drill cuttings will be placed in 55-gallon drums wrapped in plastic or spread around the boring <br /> and left on site for disposal by the site owner If requested, Kleinfelder can coordinate disposal <br /> of soil and water after analytical results are available <br /> 20-4439-01 E03/2002RO 10 Page A-3 <br /> Copyright 2002, Kleinfelder Inc January 23, 2002 <br />