My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0003097
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
1702
>
3500 - Local Oversight Program
>
PR0545315
>
ARCHIVED REPORTS_XR0003097
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2020 11:44:48 AM
Creation date
2/11/2020 9:52:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0003097
RECORD_ID
PR0545315
PE
3528
FACILITY_ID
FA0003572
FACILITY_NAME
DAVES UNION SERVICE
STREET_NUMBER
1702
STREET_NAME
JACKSON
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
227-14-011
CURRENT_STATUS
02
SITE_LOCATION
1702 JACKSON ST
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> RESNA Indust APZWP#A <br /> nes Inc <br /> Quality Assurance/Quality Control Plan <br /> Revised November 1992 <br /> 7.0 FIELD EQUIPMENT CALIBRATION AND MAINTENANCE <br /> The following measuring equipment may be used during the Remedial Investigation. Equipment <br /> ' is grouped by field activity Calibration procedures and frequency are listed by piece. <br /> Soil Borin s and Well DimensionS <br /> ' Steel and coated cloth tape Calibration: none. <br /> Water Level Measurements in Wells <br /> Steel surveyors tape. Calibration manufacturer supplied temperature correction will be <br /> applied as applicable for Feld conditions. Electrical well sounders. Calibration: check <br /> against steel surveyor's tape. <br /> Organic Vapors <br /> ' Photoionization Detector (PID) Calibration daily field calibration using a isobutylene <br /> standard as per manufacturers instructions <br /> roundwater pH Measurement <br /> IDigital pH meter. Calibration- standard pH solutions of 4, 7, and 10 will be utilized for <br /> daily field calibration according to manufacturers instructions. <br /> Electrical Conductivity <br /> Electrical Conductivity meter Calibration: factory-calibrated annually and periodically <br /> calibrated against laboratory prepared standard calibration solution. <br /> Water.Temperature <br /> Mercury or digital thermometers Calibration- factory calibrated once <br /> QAQCIM FNL <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.