Laserfiche WebLink
Table 4 Summary of Soil Vapor Extraction and Treatment System Data,ARCO Station 434,Lodi,California <br /> Start-up date 6/3191 <br /> Sample Average flow Days in Down days Percent Influent concentration ppmv a Removal te,lbs/day. Net removal lbs&gallons <br /> date Period rate cfm period in penod operational TPH-G B TPH-G B TPH-G 13 <br /> 1014/94 9127/94-10/4194 62 7 0 100% 130 <0007 3 0 21 lbs 0 lbs <br /> 11/3/94 10/4/9411/3/94 62 30 1 97% 340 <0083 8 0 228 lbs 0 lbs <br /> 1219194 1113/9412/27/94 62 54 2 96% 110 <0012 3 0 132 lbs 0 lbs <br /> 116195 12127/94-1/18195 60 22 3 7 83% 76 0035 2 0 31 lbs 0 lbs <br /> 2/6/95 1118/95-2/13/95 53 26 161 38% 140 11 3 0 28 lbs 0 lbs <br /> 317195 2113/95-3116195 55 31 3 2 90% 89 0 18 2 0 51 lbs 0 lbs <br /> 415/95 3/16/95-4/5195 60 29 0 100% 24 0 1 0 16 lbs 0 lbs <br /> 5111195 (b) 415/95-5/11195 20 36 22 39% 33 0 0 0 3 lbs 0 lbs <br /> 5118195 5/11195-5/18/95 20 7 0 100% 66 0 0 0 3 lbs 0 lbs <br /> 5126/95 5/18/95-5126195 20 8 0 100% 80 0 1 0 5 lbs 0 lbs <br /> 6/21/95 5126/95-6121/95 22 26 0 100% 44 0 0 0 9 lbs 0 lbs <br /> Totals and averages 4/5/95-6121195 28 106 22 79% 49 000 0 0 37 lbs 0 lbs <br /> for reporting period 6 gals 0 gals <br /> Totals and averages 613191-6/21/95 85 1488 113 92% 1189 5 45 0 50790 lbs 153 lbs <br /> cumulative <br /> 8192 gals 21 gals <br /> Sample calculations <br /> Removal rate calculation <br /> lbs/day=(gm/mole)*(umole/mole)*(moles110E+6 umoles)*(IOE+3 mg/gm)*(1 177 mole/cubic feet)*(2 204640E-6 lb/mg)*(60 min/hr)*(cubic feet/min)*(24 hrs/day) <br /> where(gm/mole)is molecular weight,(umoles/mole)is ppm influent concentration,molecular weights of TPH-G and Benzene are 100 2 and 78 1,respectively <br /> For pounds cumulative removal we used the removal Ib/day result and multiplied it by the difference in the number of days between the current and previous sampling event <br /> Gallons removal calculation(for TPH) <br /> gallons removed—lbs* allon/densit in lbs(density for TPH-G is 6 2 benzene is 7 32 <br /> (a)From start-up through June 1992 influent samples were not taken because there was no sample tap on the inlet to the catalytic oxidizer <br /> Therefore,the influent concentrations(in parts per million by volume)are an estimate <br /> (b)The catlytic oxidizer was tyaken off-line and replaced with a btofilter system on 5111/95 <br />