C d <br /> EXHIBIT A <br /> DESCRIPTION OF FIELD METHODS <br /> Measurements of the static water level were taken in each well prior to commencing <br /> development, and a check for floating product was also made at that time. <br /> Prior to sample collection, groundwater was purged from each monitoring well by Brown and <br /> Caldwell Consultants personnel using the Well Wizards. The purged groundwater was stored in <br /> covered 55-gallon drums on site. While purging groundwater from each well, the pH. specific <br /> conductance, and volume of water purged was monitored. Approximately three well volumes <br /> of groundwater were evacuated from all sampled monitoring wells. <br /> The wells were sampled using disposal polyvinyl chloride bailers equipped with bottom-emptying <br /> valves. The sample was drained directly from the bottom valve into four 40-milliliter glass <br /> bottles with teflon-lined septums. The samples were stored on ice from the time of collection <br /> through delivery to Brown and Caldwell's state-certified laboratory. <br /> All groundwater produced during the sampling activity was removed from the site by Armour <br /> Petroleum Services. <br />