My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012744
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
3500 - Local Oversight Program
>
PR0545339
>
ARCHIVED REPORTS_XR0012744
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2020 7:22:06 PM
Creation date
2/11/2020 4:43:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012744
RECORD_ID
PR0545339
PE
3528
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
02
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z <br /> Site Safety Plan <br /> ARCO Station Na. 2076, Lodi, California <br /> 4, Positive Pressure Leak Check: Close opening in the exhalation valve guard by <br /> placing palm of one hand over face of guard;exhale slowly maintaining slight <br /> positive pressure. No leakage should be detected between the face seal and <br /> the face. <br /> 5. Should any leakage be noted: <br /> a) Adjust the headstraps and face piece slightly; recheck for leakage. <br /> ,., b) Check condition of exhalation valve and seat. Check that both inlet <br /> gaskets are present and in proper conaition. <br /> C) In the event the face piece cannot be adjusted so there is no leakage, <br /> DO NOT ENTER THE AREA REQUIRING PROTECTION. Due <br /> to your particular facial features, a different style or size face piece <br /> ' may be required to obtain a proper facial fit. <br /> Note: Failure to perform a qualitative fit test of the respirator each time the <br /> respirator is donned may result in little or no respiratory protection. <br /> Inspection, Cleaning;, and Storage <br /> The respirator should be inspected, cleaned, and properly storea after use each day. The <br /> following steps are the basic elements of each procedure: <br /> A. Inspection <br /> 1. Examine face seal for rips, tears, holes, deformation. or stiffness. <br /> 2. Examine face piece plastic center shell for cracks, missing components, or <br /> damaged threads. <br /> 3. Examine harness for breaks, cuts, frays, tears, and Hissing or damaged <br /> hardware. <br /> 4. Examine inhalation and exhalation valves and valve seats for cuts, cracks, or <br /> foreign matter which may not allow tite valve to close completely. Check that <br /> valves are properly installed and are not distorted. <br /> --- --- ------ --- ---5.- -Examine_cartridges_for signs_ of abuse or damage. Discard damaged items. <br /> 3M-35 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.