My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0004130
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
3500 - Local Oversight Program
>
PR0545342
>
ARCHIVED REPORTS_XR0004130
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 3:46:59 PM
Creation date
2/12/2020 9:07:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0004130
RECORD_ID
PR0545342
PE
3528
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
02
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 30 June 1999 <br /> AGE-NC Project No 99-0624 <br /> r Page 8 of 10 - <br /> 4 4 MONITORING WELL INSTALLATION PROCEDURES <br /> Proposed monitoring well borings will be completed using hollow-stem auger drilling techniques <br /> Relatively undisturbed soil samples will be collected at five-foot intervals in each of the borings <br /> using a California modified split-spoon sampler fitted with 2-inch diameter, 6-inch long brass <br /> sleeves Soil sample handling will be consistent with the procedures presented in Section 4 2 <br /> Following completion of drilling the boring, a 2-inch diameter Schedule 40 PVC 0 010-inch slotted <br /> well screen and casing will be installed Twenty feet of screen will be installed in each well, <br /> extending approximately 13 feet below and seven feet above the top of the ground water table <br /> The well casing,filter pack and sealing materials will be placed into the borehole through the intenor <br /> of the hollow-stem augers After installing the well casing, filter pack material consisting of pre- <br /> washed #2112 Lonestar sand will be added from the bottom of the borehole to approximately two <br /> feet above the screened interval Following placement of the filter pack, the well will be surged to <br /> assist in settling the falter pack Additional sand will be added if settling occurs <br /> A nominal two-foot bentonite seal will be placed above the filter pack to minimize potential for <br /> grout penetration into the screened section of the well The bentonite seal will be formed by pounng <br /> bentonite chaps into the annular space between the auger and the well casing and allowing them to <br /> settle on the falter pack Bentonite chaps will be hydrated using five gallons of water The bentonite <br /> chaps will be allowed to hydrate for a minimum of one-half hour prior to grouting <br /> The remaining annular space above the bentonite seal will be filled to the ground surface with a <br /> cement grout The grout mixture will consist of type I/1I'portland neat cement and not more than 6 <br /> gallons of water per 94-pound sack of cement The grout will be placed by pumping through <br /> tremmie pipe The PHS-EHD will be notified for grout inspection at least 48-hours prior to <br /> conducting grouting procedures <br /> Following completion of the monitoring wells, well elevations and locations will be surveyed by a <br /> California-licensed surveyor <br /> 45 WELL DEVELOPMENT <br /> Development will consist of a combination of bailing to remove the mayor portion of fine-grained <br /> sediment from inside the well, surging,to flush out or draw in sediment from the falter pack, and <br /> additional bailing to finish the removal of sediment Development activities will be continued until <br /> field parameter (pH, electrical conductivity, and temperature) readings have stabilized <br /> Advanced GcoEmironmcntal,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.