My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1996 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:51:58 PM
Creation date
2/12/2020 10:13:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996 - 2004
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring&l!vstem Equipment mortification <br /> For Use by Unidocs Member Agencies or where approved by your Local Jurisdiction <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Re aulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one <br /> monitoring system control panel is installed at the facility,a separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be <br /> provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local <br /> agency regulating UST systems within 30 days of test date. Instructions are printed on the back of this page. <br /> A. General Information <br /> Facility Name: Shell 136146 <br /> Site Address: 7700 Moreland Ct. @ Hwy. 99 City: Stockton, CA Zip: 95212 <br /> Facility Contact Person: Balaii Contact Phone No.: (209) 957-5398 <br /> Make/Model of Monitoring System: Veeder Root Simplicity Date of Testing/Servicina: 11/26/01 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: 01 -Regular Tank ID: 02-Plus <br /> C1 In-Tank Gauging Probe. Model: VR 847390.107 a In-Tank Gauging Probe. Model: VR 847390.107 <br /> a Annular Space or Vault Sensor. Model: VR 794380.302 a Annular Space or Vault Sensor. Model: VR 794380.302 <br /> a Piping Sump\Trench Sensor(s). Model: VR 794380-208 a Piping Sump\Trench Sensor(s). Model: VR 794380-208 <br /> ❑ Fill Sump Sensor(s). Model: None ❑ Fill Sump Sensor(s). Model: None <br /> ❑ Mechanical Line Leak Detector. Model: None ❑ Mechanical Line Leak Detector. Model: None <br /> I& Electronic Line Leak Detector. Model: VR 331196.001 a Electronic Line Leak Detector. Model: VR 331196.001 <br /> ❑ Tank Overfill\High-Level Sensor. Model: None ❑ Tank Overfill',High-Level Sensor. Model: None <br /> N Dispenser Containment Sensor(s). Model: VR 794380.321 Z Dispenser Containment Sensor(s). Model: VR 794386.321 <br /> a Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> ❑ Other(specify equipment type and model in Section L on Page') ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID- 03-Premium Tank ID- 04- G-C— <br /> ® In-Tank Gauging Probe. Model: VR 847390-107 ❑ In-Tank Gauging Probe. Model: None <br /> ® Annular Space or Vault Sensor. Model: VR 794380.302 ® Annular Space or Vault Sensor. Model: VR 794396-420 <br /> Piping Sump ,Trench Sensor(s). Model: VR 794380-208 ❑ Piping Sump\Trench Sensor(s). Model: None <br /> ❑ Fill Sump Sensor(s). Model: None ❑ Fill Sump Sensor(s). Model: None <br /> ❑ Mechanical Line Leak Detector. Model: None ❑ Mechanical Line Leak Detector. Model: None <br /> ® Electronic Line Leak Detector. Model: VR 331196-001 ❑ Electronic Line Leak Detector. Model: None <br /> ❑ Tank Overfill\High-Level Sensor. Model: None ❑ Tank Overfill\High-Level Sensor. Model: None <br /> a Dispenser Containment Sensor(s). Model: VR 794380.321 ❑ Dispenser Containment Sensor(s). Model:_ <br /> a Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g. manufactures' checklists ) necessary to <br /> verify that this information is correct and a Site Plan showing the layout of monitoring equipment. For any equipment <br /> capable of generating such reports,I have also attached a copy of the (check all that apply): ❑ System set-up report, <br /> ❑ Alarm histor,, report. <br /> Technician:Mame(print): SSS-Ron W. Cert./Lic. No.: 290-62-0088 Signature: On file at SSS <br /> Testing Company Name: Ser. Sta. Sys. Phone No.: (408) 971-2445 <br />
The URL can be used to link to this page
Your browser does not support the video tag.