My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1996 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:51:58 PM
Creation date
2/12/2020 10:13:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996 - 2004
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VP <br /> MONITORING SYSTEM EQUIPMENT CERIFICATION <br /> State and local laws regulations require that equipment which monitors tanks and/or piping systems containing hazardous <br /> materials be tested/serviced annually or on a schedule specified by the manufacturer,whichever is more frequent. This form,or a <br /> service report with equivalent information,must be used to document testing and servicing of monitoring equipment. If more <br /> than one monitoring system(e.g.Veeder-Root TLS-350,Ronan X76S,etc.)is installed at the facility,a separate certification or <br /> report must be prepared for each monitoring system by the technician who performs the work. <br /> Date of Testing/Servicing: 4-6-00 Facility Name: Shell <br /> Site Address: 7700 Moreland City: Stockton Zip: 95212 <br /> Facility Contact Person: Waters Contact Phone No.: (209)957-5398 <br /> Make/Model of Monitoring System: Veeder Root/Simplicity Location of Control Panel: Back Room <br /> Make/Model of Line Leak Detector(LLD): Veeder Root/PLLD LLD Leak Threshold: 3.0 g.p.h. <br /> Complete the following checklist: <br /> X Yes No* Monitoring system is operable per manufacturer's specifications? <br /> X Yes No* Audible alarm isoperational? <br /> X Yes No* Visual alarm isoperational? <br /> X Yes No* Monitoring system is secured from unauthorized tampering? <br /> X Yes No* For pressurized piping systems,do the turbines automatically shut down if the monitoring system detects a leak,fails <br /> to_Qperate,or is electrically disconnected? If yes,which monitoring devices initiate positive shut down? <br /> N/A <br /> PLLD/Sump Sensors <br /> X Yes No* For monitoring systems which serve as tank overfill warning devices,does the overfill warning function operate <br /> properly? If so,at what percent of tank capacity does the alarm trigger? 90% <br /> N/A <br /> *In the comments section below,describe how and when these deficiencies will be corrected. <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID No.: Regular Tank ID No.: Plus Tank ID No.: Premium Tank ID No.: Waste Oil <br /> Annular Space Sensor X Annular Space Sensor Annular Space Sensor X Annular Space Sensor <br /> Piping Surnp Sensor X Piping Sump Sensor X Piping Sump Sensor Piping Sump Sensor <br /> In-Tank Gauging Probe X In-Tank Gauging Probe X In-Tank Gauging Probe In-Tank Gauging Probe <br /> Dispenser Containment Sensor(s) X Dispenser Containment Sensor(s) X Dispenser Containment Sensor(s) Dispenser Containment Sensor(s) <br /> Mechanical Line Leak Detector Mechanical Line Leak Detector Mechanical Line Leak Detector Mechanical Line Leak Detector <br /> Electronic Line Leak Detector X1 Electronic Line Leak Detector Electronic Line Leak Detector Electronic Line Leak Detector <br /> Fill Sump Sensor Fill Sump Sensor Fill Sump Sensor X Fill Sump Sensor <br /> TLM Sump Sensor TLM Sump Sensor TLM Sump Sensor TLM Sump Sensor <br /> Are impact valves operational per manufacturer's specifications? X I YES NO <br /> Comments: <br /> I certify that the equipment identified above was inspected/serviced in accordance with manufacturers' guidelines. <br /> Attached to this Certification is information(e.g.manufacturer's checklist,etc.)necessary to verify that the above <br /> information is correct and to describe any repairs,replacement,or recalibration of equipment. <br /> Name of Qualified Technician(print): John Talbott Signature: Signature on file at SSS. <br /> Testing Company Name: Service Station Systems,Inc. Phone No.: (408)971-2445 <br />
The URL can be used to link to this page
Your browser does not support the video tag.