My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1996 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:51:58 PM
Creation date
2/12/2020 10:13:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996 - 2004
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Edition:September 1997 <br /> Veeder-Root <br /> TLS-350 ! 35OPC / 350R/35ORPC Line Leak Detector, Series 8484 <br /> AUTOMATIC ELECTRONIC LINE LEAK DETECTOR <br /> Certification: Leak rate of 3.0 gph with P:)=100.09'o and P=.%=O%. <br /> Leak Threshold: 1.88 gph. A leak is declared if the output of the measurement system equals or <br /> exceeds this threshold. <br /> Applicability: Gasoline, diesel, aviation fuel, and solvents. <br /> Specification: System tests pressurized fiberglass and steel pipelines. <br /> Tests are conducted at operating pressure. <br /> System will not function with a mechanical line leak detector installed <br /> in the pipeline. <br /> Pipeline Capacity: Maximum of 98.4 gallons. <br /> Waiting Time: None between delivery and testing. <br /> Minimum of 16 minutes between dispensing and testing. <br /> Test Period: Response time is 28.8 seconds. <br /> Test data are acquired and recorded by a microprocessor. <br /> Calculations are automatically performed by the microprocessor. <br /> System Features: Permanent installation on pipeline. <br /> Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Dispenser shutdown, message display and alarm activation if leak is declared. <br /> Calibration: System must be checked annually and calibrated if necessary in accordance with <br /> manufacturer's instructions. <br /> Veeder-Root Evaluator: Midwest Research Institute <br /> 125 Powder Forest Dr. Tel: (816) 753-7600 <br /> Simsbury, CT 06070-2003 <br /> Tel: (203) 651-2700 Date of Evaluation: 08/07/91 <br /> 279 <br /> Appearance on this list is not to be construed as an endorsement by any regulator/agency nor is it any guarantee of the performance of <br /> the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.