COMPLIANCE INFO_1996 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1996 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:51:58 PM
Creation date
2/12/2020 10:13:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996 - 2004
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEC-23-2004 12:47 SERUICE STATION SYSTEM 408 971 0135 P.03 <br /> Monitor* System Equipmenkertification <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited., Chapter 67, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofRegulutions <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certiScat-_gn or report must be <br /> prepared for each monitoring system control panel by the technician who pe'Ifonns the work.A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within.10 days of test date. <br /> A. General Information <br /> Facility Name:99 Shell Bldg.No.: <br /> Site Address: 7700 Moreland Ct. @ Hwy, 99 City: Stockton, CA Zip: 95212 <br /> Facility Contact Person:' E"\f `U� Contact Phone No.: (209)957-5398 <br /> Make/Model of Monitoring System: V/R Simplicity Date of Testing/Servicing: 11 ID4� <br /> B. Inventory of Equipment Tested/Certified )4 /(A <br /> Cluck the appropriane boxes to indicate specific equipment hnspeeted/serviced: <br /> Tank ID;01- eau Tank ID: 02-Plus <br /> In-Tank Gauging Probe. Model: VR$47390-107 Tank Gauging Probe, Model: YR 847390-107 <br /> Annular Space or Vault Sensor. Model: VR 794340302 t%Annular',Pane or Vault Sensor. 'Model: VR 794380302 <br /> W/Piping Sump\Trench Sensor(s). Modcl: VR 784380-208 K Piping Sump\Trench Sensor(s). Model: VR 794380-208 <br /> 0 Fill Sump Sensor(a). Model: None 0 Fill Sump Sensor(s). Model: None <br /> o Mechanical Line Leak Detector. Model: None Q Mechanical Line Leak Detector. Model: None <br /> Electronic Linc Leak Detector, Model: VR Sormi;8484 Flectmnic Line Leak Detector. Model: VR Series 8484 <br /> [] Tank Overfill\Nigh-Level Sensor. ':Model: None 0 Tank Overfill\High-Level Sensor. Model: None <br /> p Other(specify equipment type and model in Section Eon Page 2). Q Olhcr(specify equipmetit type and model in Section Pon Page 2). <br /> T'�Rk ID: 03-Prem Tank ID; 04-Waste Oil <br /> i-Tank auging Probe. el: VR 847390.107 Q In-Tank Gauging Probe. Model: None <br /> Annular Space or Vault Sensor. Model: VR 794380302 yAnnular Space or Vault Sensor, Model: VR 794390-420 <br /> Piping Sump\Trench Sensor(s). Model: VR 79380 <br /> 4 -208 0 Piping Sump\Trench Scnsor(s). Model: None <br /> 0 Fill Sump Scnsor(s). Model: Non. O Fill Sump Sensor(s)_ Model; Non. _ <br /> (] Mechanical Linc Leak Detector, Model: Non• Q Mechanical Line Leak Detector, Model: None <br /> Electronic Line Leak Detector. Model; VR Series 8484 Q Electronic Linc Leak Detector, Model: None <br /> 0 Tank Overfill\High.t.evel Sensor. Model: None T <br /> ank Overfill 1 High-Level Sensor. ,Model: VR 794390.420 <br /> Q 011ier(specify equipment type and model in Section 1 on Page 2). !a Other(specify equipment type and model in Section F-on Page 2). <br /> Dispenser ID: 01-02Dispenser 1D: 03-04 <br /> Dispenser Containment Sensor(s). Mode: VR 794380-221 IklDispenser Containment Sensor(s). Model; VR 7[14390.321 <br /> Shear Valve(s), Shear Valve(s). <br /> Dispenser Containment Float(s)acid Chain(s). 0 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 05-06 Dispenser ID: 07-08 <br /> l Dispenscr Containment Sensor s). del: VR 794380-''21 Dispcnscr Containment Sensor(s). Mode: VR 794380.321 <br /> X Shear Valve(s). shear Valve(s). <br /> I] Dispenser Containment Float(s)and Chain(s). C) Dispenser Containment Float(s)and Chain(s), <br /> Dispenser ID: Dispenser ID: <br /> 0 DispnrtserContainment Sensor(n). Model! 7 Q DispcnaerContananen[Srnsvr(s), ModcL ? <br /> 0 sheat'Valve(s). 0 Shcar Valve(s). <br /> C Dispenser Containment Float(s)and Chain(s). 0 Dispenser Containmcnl Floal(s)and Chain(s). <br /> *Ifthc facility contains more tanks or dispensers,copy this form.Include inforzmtion for every tank and dispenser at the facility <br /> C. Certification- I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g,manufactures'checklists)necessary to verify that this <br /> information is correct azul a Plot Plan showing the layout of monitoring equiplueut. For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (check all theirapply).- Q System set-up Q Alar ' tory relic <br /> Technician Name(print):SSS-Tedi fly Signature: <br /> Certification No.: W6— b 5" p 11. 5 Ire License.No,"'485184 <br /> Testing Company Name:Ser. Sta. Sys. Phone No.: (408)979-2445 <br /> Site Address: 7700 Moreland Ct. @ Hwy. 99 Date of Testing/Servicing: P13 r <br />