Site Preparatio 4 Installation Instructions T <br /> TI.,)-350 UST Monitoring System <br /> Typical Sensor and Probe Junction Boxes: FAILURE TO COMPLY WITH THESE WARN- <br /> INGS COULD RESULT IN DEATH, SERIOUS <br /> Manufacturer: Appleton Electric Co. PERSONAL INJURY,PROPERTY LOSS AND <br /> 1701 W.Wellington Avenue EQUIPMENT DAMAGE. <br /> Chicago,IL 60657 <br /> Tel: (312)327-7200 All wires must be of a type designed for use in the presence <br /> of gasoline and oil, and must be between AWG 18 and <br /> AWG 14. The conduit must be properly sealed in accor- <br /> dance with the National Electrical Code (NFPA 70)and <br /> Junction Box JBDX-75 1 the Automotive and Marine Service Station Code(NFPA <br /> Cover,Junction Box JBK-B 1 30A)since they pass from a Class 1,Division I or Division <br /> H area into a nonhazardous area. <br /> Gasket,Junction Box JB-GK-V 1 <br /> 16 CAUTION.IT IS CRITICAL THAT YOU IDENTIFY <br /> AND MAINTAIN THE RELATIONSHIP OF PROBE <br /> • Manufacturer: Crouse-Hinds Co. AND SENSOR LOCATIONS AND THEIR WIRES <br /> Syracuse,NY 13221 TO THEIR POSITIONS ON THE PROBE OR SEN- <br /> Tel: (316)477-7000 SOR CONNECTORS.FAILURE TO DO SO COULD <br /> RESULT IN THE IMPROPER IDENTIFICATION <br /> OF A LEAK LOCATION OR LEAK TYPE.APPEN- <br /> Descrlptlon Catalog Number Quantity DIX A PROVIDES A FORM TO RECORD THE <br /> Junction Box GRFX-139 1 COLOR CODING OR LABELING METHOD USED <br /> TO IDENTIFY THE WIRING SCHEME. <br /> Cover,Junction Box GRF-10 1 <br /> Gasket,Junction Box GASK-643 1 1.Two-Wire Probe and Sensor Wiring. <br /> Pull two conductors of color-coded,THWN AWG 14-18 <br /> stranded copper wire between the TLS-350 monitor <br /> G. MANHOLE INSTALLATION. and the junction box at each probe and sensor loca- <br /> tion. <br /> .1 NOTE:Ensure that there is a sufficient amount of <br /> gravel under each manhole for proper drainage. Since the wires for multiple probes and sensors may <br /> enter the TLS-350 monitor through a single conduit, <br /> At each probe and sensor location,install a 14-inch mini- be sure to use a different color code for each wire or <br /> mum diameter approved manhole according to the individually mark each wire! <br /> manufacturer's instructions. Offset the probe or sensor 2. Three-Wire Sensor Wiring. <br /> riser pipes within the manholes for ease of junction box <br /> installation and wiring.Leave enough space between the Pull three conductors of color-coded, THWN AWG <br /> junction box and manhole liner so that the junction box 14-18 stranded copper wire between the TLS-350 <br /> can be removed if necessary. monitor and the junction box at each monitoring well <br /> location. <br /> H.INTRINSICALLY SAFE WIRING INSTALLATION. <br /> Since the wires for multiple sensors may enter the <br /> (See Figures 9a and 9b,`Typical TLS-350 System Wiring TLS-350 monitor through a single conduit,be sure to <br /> Diagrams"). use a different color code for each wire or individually <br /> To the installer:Read and carefully adhere to the instruc- mark each wire! <br /> tions in the following warnings during intrinsically <br /> safe-wire(field wire)installation! I.POWER WIRE INSTALLATION. <br /> WARNING:IMPROPER SYSTEM OPERATION (See Figures 9a and 9b,`Typical TLS-350 System Wiring <br /> COULD RESULT IN UNDETECTED POTEN- Diagrams"). <br /> TIAL ENVIRONMENTAL AND HEALTH HAZ- <br /> ARDS IF THE PROBE-OR SENSOR-TO-MONI- Pull four(4)wires between the power panel and the TLS- <br /> TOR WIRE RUNS EXCEED 1000 FEET.RUNS 350 monitor; three (3) #14 AWG (or larger) color-coded <br /> OVER 1000 FEET ARE NOT UL ACCEPTED wires for line,neutral and chassis ground;and,one(1)#12 <br /> FOR THIS APPLICATION. PROBE- AND AWG wire for barrier ground. <br /> SENSOR-TO-MONITOR WIRES MUST NOT <br /> EXCEED 1000 FEET. CAUTION: DO NOT CONNECT THE POWER <br /> WARNING: EXPLOSION COULD OCCUR IF SUPPLY WIRES TO A LIVE CIRCUIT. <br /> OTHER WIRES SHARE CONDUITS OR <br /> TROUGHS WITH PROBE OR SENSOR WIR- <br /> ING. CONDUITS AND WIRING TROUGHS <br /> FROM TLS-350 PROBES AND SENSORS MUST <br /> NOT CONTAIN ANY OTHER WIRES. <br /> 9 <br />