My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1996 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:51:58 PM
Creation date
2/12/2020 10:13:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996 - 2004
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Preparatio id Installation Instructions <br /> TLS-350 UST Monitoring System <br /> D.POWER WIRING CONNECTIONS. 4. Connect the power supply wires in the power panel to <br /> WARNING: IN INSTALLATION OF THIS a separate dedicated circuit. <br /> PRODUCT, COMPLY WITH THE NATIONAL 5. Check to be sure that the electrical resistance between <br /> ELECTRICAL CODE;FEDERAL,STATE,AND the monitor ground terminal and a known good earth <br /> LOCAL CODES; AND ANY OTHER APPLI- ground is less than IQ. <br /> CABLE SAFETY CODES.IN ADDITION,TAKE E.PROBE AND SENSOR WIRING CONNECTIONS. <br /> NECESSARY PRECAUTIONS DURING IN- <br /> STALLATION, SERVICE AND REPAIR TO WARNING: IN INSTALLATION OF THIS <br /> PREVENT PERSONAL INJURY, PROPERTY PRODUCT, COMPLY WITH THE NATIONAL <br /> LOSS AND EQUIPMENT DAMAGE. ELECRICAL CODE; FEDERAL, STATE,AND <br /> WARNING:BE SURE POWER TO THE TLS-350 LOCAL CODES; AND ANY OTHER APPLI- <br /> CABLE SAFETY CODES.IN ADDITION,TAKE <br /> CIRCUIT IS TURNED OFF BEFORE CON- NECESSARY PRECAUTIONS DURING IN- <br /> NECTING POWER WIRING.FAILURE TO DO STALLATION, SERVICE AND REPAIR TO <br /> SO COULD RESULT IN DEATH, SERIOUS PREVENT PERSONAL INJURY, PROPERTY <br /> PERSONAL INJURY, PROPERTY LOSS AND LOSS AND EQUIPMENT DAMAGE. <br /> EQUIPMENT DAMAGE. WARNING:BE SURE AC POWER TO THE SYS- <br /> Power Supply Rating. ih TEM IS OFF BEFORE OPENING THE <br /> FRONT-PANEL COVER AND CONNECTING <br /> Input Power:(L',N,G); 120 VAC,50/60 Hz,10OW Max. PROBE AND SENSOR WIRES.IF HIGH VOLT- <br /> AGE IS SHORTED ACROSS ANY BARRIER <br /> Output Power:Alarm Relay Contacts, resistive load— TERMINAL, EXPLOSION AND FIRE COULD <br /> 120 VAC,2A Max.;or, 24 VDC, 2A Max. RESULT. <br /> 1. Connect a# 12 AWG(or larger)barrier ground conduc- Connectors are supplied with each sensor and probe <br /> for from the ground lug closest to the conduit entry in module.They provide screw terminations for each sensor <br /> the monitor to the earth ground bus on the power panel and probe. <br /> being used to supply AC line voltage to the TLS-350 CAUTION• ONCE PROBES AND SENSORS <br /> monitor(see Figure 11,"Power Wiring Diagram"). 16 HAVE BEEN CONNECTED AND THE SYSTEM <br /> 16 NOTE:If connecting to a subpanel,be sure there is HAS BEEN STARTED AND PROGRAMMED, <br /> an earth ground connection between the subpanel MODULE POSITIONS,CONNECTOR POSITIONS <br /> and the main power panel in accordance with the AND WIRE POSITIONS CANNOT BE CHANGED <br /> National Electrical Code. WITHOUT REPROGRAMMING THE SYSTEM! <br /> 2. Connect the power wires (L' and N) to the proper IMPROPER SYSTEM OPERATION WILL RESULT <br /> IF ANY ONE OF THESE POSITIONS IS <br /> terminals in the AC connector(see Figure 11). CHANGED WITHOUT REPROGRAMMING. <br /> 3. Connect the chassis ground wire from the ground lug Be sure to accurately record on the circuit directory the <br /> closest to the conduit entry in the monitor to the earth type of module, and the location of each device wired to <br /> ground bus on the power panel being used to supply the connector. <br /> AC line voltage to the TLS-350 monitor(see Figure 11, <br /> "Power Wiring Diagram"). Identify each connector with a self-adhesive number la- <br /> bel according to the slot number. <br /> GROUND LUG 1A FUSE 3AG SLO-BLO 1. Two-Wire Probes and Sensors. <br /> EI-. Connect the two color-coded or marked wires from <br /> E0 <br /> ® M o each probe or sensor to the appropriate terminals in <br /> ® ® the probe or sensor module connectors (see Figure 12, <br /> "Four Probe/Thermistor Interface Module Wiring Dia- <br /> gram"and Figure 13,"Interstitial Liquid Sensor Inter- <br /> MODULE face Module Diagram.") <br /> • 0 0 CONNECTOR Be sure to maintain proper polarity between the <br /> GROUND LUG <br /> CLOSEST TO probe wires and their respective module connector <br /> CONDUIT ENTRY terminations, Since interstitial liquid sensors are con- <br /> tact switches, polarity is not a consideration when con- <br /> ® ® necting field wires to interface modules. <br /> 2. Three-Wire Vapor Sensors. <br /> Connect the three color-coded or marked wires from <br /> o MONITOR each vapor sensor to the appropriate terminals in the <br /> RIGID a ° vapor sensor module connectors(see Figure 14,"Vapor <br /> CONDUIT E Sensor Interface Module Wiring Diagram"). Be sure <br /> to maintain proper polarity between the vapor <br /> N L, <br /> sensor wires and their respective module con- <br /> Figure 11. Power Wiring Diagram. nector terminations. <br /> 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.