Site Preparatic nd Installation Instructions <br /> T.L----350 UST Monitoring System <br /> 8. Seal wire nuts with epoxy sealant furnished with each mlm WARNING:TO AVOID ELECTRICAL SHOCK <br /> probe,using one bag for two wire nut connections.(See WHICH COULD KILL YOU, BE SURE AC <br /> Figure 26,"Epoxy Sealant for Two-Wire Connections.") POWER TO THE TIS MONITOR IS OFF DUR- <br /> ING INSTALLATION. <br /> TO SENSOR TO MONITOR ABOVEGROUND STORAGE TANK APPLICA- <br /> TIONS:Installation Kit No.312020-984 is required <br /> for magnetostrictictive probe installation in <br /> aboveground storage tanks.The kit includes: <br /> 1-Adaptor,Part No. 329972-001 <br /> 1- 5-foot length of 3/8" Flex Conduit, Part <br /> No.576008-294 <br /> TIE WRAP 2 - 3/8" Straight Liquidtight Connectors, <br /> Part No. 576008-295 <br /> / Iih WARNING:BE CAREFUL TO MAINTAIN <br /> YOUR BALANCE WHEN WORKING ON <br /> PACKET TOP OF THE STORAGE TANK. TANK <br /> SURFACE IS VERY SLIPPERY. <br /> CAUTION:IT IS RECOMMENDED THAT <br /> THE RISER PIPE BE A LIGHT COLOR <br /> WIRE NUTS TO REFLECT SUNLIGHT AND TO MAIN- <br /> EPDXY SEALANT TAIN A REASONABLE TEMPERATURE. <br /> PROBE MAY NOT FUNCTION PROP- <br /> Figure 26.Epoxy Sealant for Two-Wire Connections. ERLY IF THE TEMPERATURE IN THE <br /> RISER IS ABOVE 700. <br /> 16 CAUTION: IF MORE THAN TWO WIRE NUT <br /> CONNECTIONS SHARE AN EPDXY SEALANT A.TANK DIAMETER MEASUREMENT. <br /> BAG,THE CONNECTIONS WILL NOT BE PROP- <br /> ERLY SEALED. IMPROPER SEALING OF THE Perform the following procedure to ensure that probes are <br /> CONNECTIONS WILL RESULT IN INACCURATE installed in the proper tanks(see Figure 27,"Tank Diam- <br /> PROBE READINGS AND POSSIBLY FALSE eter Measurement"). Inaccurate readings will result if <br /> ALARM CONDITIONS. probes are not the correct length for the given tank <br /> WARNING: EPDXY SEALANT MAY BE IRRI- diameter. <br /> TATING TO EYES AND SKIN. MAY CAUSE 1. Measure the distance from the bottom of the tank to the <br /> SKIN SENSITIZATION IN SUSCEPTIBLE IN- top of the probe riser pipe (a). <br /> DIVIDUALS.MAY BE ABSORBED THROUGH <br /> THE SHIN.EPDXY SEALANT CONTAINS EP- 2. Measure the distance from the bottom of the probe riser <br /> OXY RESIN AND VINYL CYCLOHEXENE DI- pipe to the top of the probe riser pipe(b). <br /> OXIDE.VINYL CYCLOHEXENE DIOXIDE HAS <br /> CAUSED SKIN CANCER IN ANIMAL TESTS. 3. Subtract (b) from (a) to determine the correct tank <br /> PRECAUTIONS:AVOID EYE AND SKIN CON- <br /> diameter(c). <br /> TACT. WEAR IMPERVIOUS GLOVES AND 4. Make sure the probe length(see Figure 28,"Magnetos- <br /> SAFETY GLASSES.USE ONLY IN WELL VEN- trictive Probe Dimensions") is correct for the tank <br /> TILATED AREAS. <br /> diameter. <br /> 9. Tighten the cable bushing nuts on the probe riser cap <br /> and junction box to ensure a water-tight seal at the <br /> probe cable entry. <br /> PROBE RISER PIPE <br /> 10.Secure the riser locking cap to the top of the riser pipe. TANK <br /> A padlock may be installed for added security. <br /> b <br /> SECTION 6. MAGNETOSTRICTIVE PROBE a <br /> INSTALLATION C a-b-c <br /> 12 WARNING: TO PROTECT YOURSELF AND <br /> OTHERS FROM BEING STRUCK BY VE- <br /> HICLES DURING WORK, BLOCK OFF YOUR <br /> WORK AREA DURING INSTALLATION AND <br /> SERVICE. Figure 27. Tank Diameter Measurement. <br /> 23 <br />