2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1996 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:51:58 PM
Creation date
2/12/2020 10:13:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996 - 2004
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F <br /> Site Preparation and Inst�tation Instructions <br /> I TLS-350 UST Monitoring System <br /> 8. Seal wire nuts with epoxy sealant using one bag for two B.SENSOR WIRING. <br /> wire nut connections. (Refer to Figure 26, "Epoxy 1. Thread the two-wire sensor cable through the riser <br /> Sealant for Two-Wire Connections.") <br /> pipe cap. <br /> CAUTION: IF MORE THAN TWO WIRE NUT 2. Using wire nuts,connect the sensor cable to the field <br /> CONNECTIONS SHARE AN EPDXY SEALANT wires in the sensor junction box. (Refer to Figure 50, <br /> BAG, THE CONNECTIONS WILL RESULT IN "Hydrostatic Sensor Wiring Installation Diagram.") <br /> INACCURATE SENSOR READINGS AND POSSI- <br /> BLY FALSE ALARM CONDITIONS. <br /> WEATHERPROOF <br /> JUNCTION BOX <br /> WARNING: EPDXY SEALANT MAY BE IRRI- (1 PER PROBE) <br /> TATING TO EYES AND SKIN. MAY CAUSE 1/2"RIGID <br /> SKIN SENSITIZATION IN SUSCEPTIBLE IN- coNDulr Blk <br /> DIVIDUALS.MAY BE ABSORBED THROUGH <br /> THE SKIN.EPDXY SEALANT CONTAINS EP- TO To <br /> MONITOR SENSOR <br /> OXY RESIN AND VINYL CYCLOHEXENE DI- <br /> OXIDE.VINYL CYCLOHEXENE DIOXIDE HAS <br /> CAUSED SKIN CANCER IN ANIMAL TESTS. <br /> PRECAUTIONS:AVOID EYE AND SKIN CON- <br /> TACT. WEAR IMPERVIOUS GLOVES AND Figure 50. Hydrostatic Sensor Wiring Installation <br /> SAFETY GLASSES.USE ONLY IN WELL VEN- Diagram. <br /> TILATED AREAS. <br /> SECTION 8. HYDROSTATIC SI VISOR 3. Seal wire nuts with epoxy sealant using one bag for two <br /> wire nut connections. (Refer to Figure 26, "Epoxy <br /> INSTALLATION Sealant for Two-Wire Connections.") <br /> NOTE: The wires between the monitor and each <br /> hydrostatic sensor location must be of a type de- CAUTION: IF MORE THAN TWO WIRE NUT <br /> signed for use in the presence of gasoline and oil,and CONNECTIONS SHARE AN EPDXY SEALANT <br /> must be between AWG 14 and AWG 18.The conduit BAG,THE CONNECTIONS WILL NOT BE PROP- <br /> must be properly sealed in accordance with the ERLY SEALED. IMPROPER SEALING OF THE <br /> National Electrical Code (NFPA 70) and the Auto- CONNECTIONS WILL RESULT ININACCURATE <br /> motive and Marine Service Station Code (NFPA SENSOR READINGS AND POSSIBLY FALSE <br /> 30A)since they pass from a Class I,Division II area ALARM CONDITIONS. <br /> into a nonhazardous area. <br /> WARNING: EPDXY SEALANT MAY BE IRRI- <br /> A.EQUIPMENT PREPARATION. TATING TO EYES AND SKIN. MAY CAUSE <br /> SKIN SENSITIZATION IN SUSCEPTIBLE IN- <br /> WARNING: TO AVOID ELECTRICAL SHOCK DIVIDUALS.MAY BE ABSORBED THROUGH <br /> WHICH COULD KILL YOU, BE SURE AC THE SKIN.EPDXY SEALANT CONTAINS EP- <br /> POWER TO THE MONITOR IS OFF DURING OXY RESIN AND VINYL CYCLOHEXENE DI- <br /> SENSOR CABLE CONNECTION. OXIDE.VINYL CYCLOHEXENE DIOXIDE HAS <br /> CAUSED SKIN CANCER IN ANIMAL TESTS. <br /> 1. Turn OFF power to the TLS-350 system before connect- PRECAUTIONS:AVOID EYE AND SKIN CON- <br /> ing the sensor cable. TACT. WEAR IMPERVIOUS GLOVES AND <br /> SAFETY GLASSES.USE ONLY IN WELL VEN- <br /> NOTE:Do not install the sensor ifbrine solution has TILATED AREAS. <br /> not been installed in the annulus,according to tank <br /> manufacturer'sspecifications.Failure tocomply may 4. Restore power to the TLS-350 system. <br /> lead to an alarm or incorrect sensor readings. <br /> C.PRE-INSTALLATION SENSOR TESTING. <br /> 2. Make sure the brine solution has had time to settle in 1. Testing Dual-Float Sensors. <br /> the annular spacebefore continuing with sensorinstal- <br /> lation.Refer to the tank manufacturer's recommenda- a. Place the sensor in a bucket of water until the water <br /> tions. level is between the upper and lower float assem- <br /> blies. <br /> 3. Install the vent in the riser pipe cap.(See cap drawing b. Immerse the upper float completely in the bucket of AL <br /> in Figures 51 and 52.) water. The TLS monitor should indicate an alarm 114opm <br /> NOTE:If installing sensor in a location with a high condition. <br /> water table,install a separate vent line routed to an c. Lift the sensor from the water until the lower float <br /> aboveground location to ensure water won't enter assembly is completely out of the water. The TLS <br /> riser pipe through the cap vent. should indicate an alarm condition. <br /> 32 <br />
The URL can be used to link to this page
Your browser does not support the video tag.