My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_1996 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:51:58 PM
Creation date
2/12/2020 10:13:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996 - 2004
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FVEEDER-ROOT SUMP S SOR <br /> INSTALLATION INSTRUIc iTONS <br /> IMPORTANT! <br /> THIS MANUAL REQUIRES ALL PRELIMINARY SITE PREPARATIONIS COMPLETED,AND THAT FIELD WIRING <br /> FROM THE MONITOR TO THE SENSOR JUNCTION BOX IS IN PLACE. IT CONTAINS INSTALLATION AND <br /> WIRING PROCEDURES FOR THE INSTALLATION OR REPLACEMENT OF A SUMP SENSOR SWITCH ONLY! <br /> FOR NEW INSTALLATIONS, REFER TO THE APPLICABLE "SITE PREPARATION AND INSTALLATION <br /> INSTRUCTIONS" MANUAL PROVIDED WITH THE SYSTEM AND LISTED IN SECTION I.A.1 OF THIS MANUAL. <br /> SECTION 1. INTRODUCTION damage caused by improper packing. Address the shipment to <br /> Veeder-Root Co., 6th Avenue at Burns Crossing, Altoona, <br /> A. GENERAL Pennsylvania 16603. <br /> 1. This manual contains installation procedures for the <br /> installation or replacement of Veeder-Root Sump Sensor, Part SECTION II. PIPING SUMP SENSOR <br /> No. 794390-205, any of the following monitoring systems INSTALLATION <br /> designed and manufactured by Veeder-Root Company:ILS-250, The sum sensor comes with the following hardware necessary <br /> TLS-2501, TLS-3001, TLS-350 or TLS-350R System. P g rY <br /> to mount it within the piping sump: <br /> This manual assumes all preliminary site preparation is com- <br /> pleted, and that field wiring from the monitor to the sensor 1 - PVC Mounting Sleeve <br /> junction box is in place. 1 - Aluminum 90° Mounting Bracket <br /> 1 - Cord Grip <br /> If site preparation is necessary,refer to the appropriate Veeder- 2 - #6-20 (.312" long) Sheet Metal Screws <br /> Root Site Preparation and Installation Instructions: ILS-250, <br /> Manual No.576013-727;TLS-250i Four-Tank(Direct-Connect) A. GENERAL The sump sensor can be mounted either of two <br /> System,Manual No.576013-579;TLS-250iEight-Tank(Indirect- ways: on the sensor junction box using the mounting bracket <br /> Connect) System, Manual No. 576013-577; TLS-3001, Manual and sleeve supplied (Figure 1); or, by cementing the PVC <br /> No. 576013-275; ILS-350, Manual No. 576013-773; TLS-350, mounting sleeve directly to the side of a fiberglass containment <br /> Manual No.576013-622;TLS-350R,Manual No.576013-879;or sump (Figure 4). <br /> contact your Veeder-Root representative for assistance. Before you install the sump sensor, there are several important <br /> 2. When a vertical bar I appears adjacent to text or illustra- requirements to consider: <br /> tions, information has been added or changed at the last 1. The sump sensor must be positioned as close to the <br /> revision date. containment sump outer wall as possible. <br /> B. DAMAGE CLAIMS 2. The sump sensor must be mounted in a true vertical position <br /> 1. Thoroughly examine all components and units as soon as to ensure proper operation of the float switch contained inside. <br /> received. If damaged,write a complete and detailed description <br /> of the damage on the face of the freight bill. Have the carrier's 3. There must be at least one inch of clearance between the <br /> agent sign the description. bottom of the mounting sleeve and the base of the sump. <br /> NOTE: Insist that the carrier's agent verify the 4. When installed, the sump sensor must rest on the base of the <br /> inspection and sign the description. sump. <br /> B. INSTALLATION. The wires between the monitor or ESA <br /> 2. Immediately notify the delivering carrier of damage or loss. module and each sump sensor location must be of a type <br /> This notification may be given either in person or by telephone. designed for use in the presence of gasoline and oil, and must <br /> Written confirmation must be mailed within 48 hours. Rail- be between AWG 14 and AWG 18. The conduit must be <br /> roads and motor carriers are understandably reluctant to make properly sealed in accordance with the National Electrical Code <br /> adjustments for damaged merchandise unless inspected and (NFPA 70) and the Automotive and Marine Service Station <br /> reported promptly. Code (NFPA 30A)since they pass from a Class I,Division I or <br /> Division II area into a nonhazardous area. <br /> 3. Risk of loss, or damage to merchandise remains with the <br /> buyer. It is the buyer's responsibility to file a claim with the <br /> carrier involved. -tts WARNING: TO AVOID ELECTRICAL <br /> 4. Immediately advise your Veeder-Root representative, SHOCK WHICH COULD KILL YOU, BE <br /> distributor,or the factory so that we may assist you. SURE AC POWER TO THE MONITOR ISOFF DURING INSTALLATION. <br /> C. RETURN SHIPPING. All shipments of Veeder-Root <br /> products must be prepaid. If the sump sensor is damaged, <br /> return it in the original shipping container with shock absorbing <br /> material provided. Veeder-Root will accept no liability for <br /> 2 <br />