Laserfiche WebLink
FVEEDER-ROOT <br /> SUMP , 1SOR <br /> INSTALLATION INSTRUIUTIONS <br /> j. Seal wire nuts with epoxy sealant using one bag for two 4. To mount the sump sensor by cementing the PVC <br /> wire nut connections. (See Figure 4, "Epoxy Sealant for Two- mounting sleeve to the sump wall (fiberglass sumps only) <br /> Wire Connections.") (Figure 5): <br /> CAUTION: IF MORE THAN TWO WIRE NUT <br /> CONNECTIONS SHARE AN EPDXY SEALANT <br /> BAG, THE CONNECTIONS WILL NOT BE <br /> PROPERLY SEALED. IMPROPER SEALING OF LEADER CABLE <br /> THE CONNECTIONS WILL RESULT IN <br /> INACCURATE SENSOR READINGS AND <br /> POSSIBLY FALSE ALARM CONDITIONS. <br /> CORD GRIP SUMP <br /> WALL <br /> TO SENSOR TO MONITOR <br /> JUNCTION BOX <br /> I I <br /> TIE WRAP II <br /> MOUNTING SLEEVE <br /> SUMP SENSOR SWITCH <br /> I <br /> PACKET Figure 5. Mounting Sleeve Cemented to Sump Wall <br /> a. Select a position for the mounting sleeve in the sump as <br /> WIRE NUTS far away from the submersible pump as possible. <br /> EPDXY SEA`ANr NOTE: The mounting sleeve must be mounted far <br /> enough into the sump to allow the sump sensor, when <br /> Figure 4. Epoxy Sealant for Two-Wire Connections. installed, to rest on the base of the sump and mounted <br /> at least one inch up from the base. <br /> NOTE: Using epoxy sealant furnished with each sensor, b. Mark a line on the sump wall indicating the top of the <br /> seal wire nut and cable connections at this time. mounting sleeve. <br /> C. Apply cement approved for use with PVC and the sump <br /> wall material generously in a line running the complete <br /> WARNINlength of the sleeve. <br /> IRRITATING <br /> EPDXY SEALANT MAY BE d. Using a level, position the sleeve vertically at the mark <br /> RRITNG TO EYES AND SKIN. MAY indicated on the sump wall and press it firmly to the side <br /> CAUSE SKIN SENSITIZATION IN <br /> SUSCEPTIBLE INDIVIDUALS. MAY BE of the sump. BE SURE THE SLEEVE IS VERTICAL. <br /> ABSORBED THROUGH THE SKIN. EPDXY e. Hold the sleeve in position until the cement has hardened. <br /> SEALANT CONTAINS EPDXY RESIN AND <br /> VINYL CYCLOHEXENE DIOXIDE. VINYL f. Install and connect the sump sensor following instructions <br /> CYCLOHEXENE DIOXIDE HAS CAUSED in Section 31 through 3.j. <br /> SKIN CANCER IN ANIMAL TESTS. <br /> PRECAUTIONS: AVOID EYE AND SKIN <br /> CONTACT. WEAR IMPERVIOUS GLOVES <br /> AND SAFETY GLASSES. USE ONLY IN <br /> WELL VENTILATED AREAS. <br /> VEEDER-ROOT <br /> Environmental Products <br /> F,-,U <br /> 125 Powder Forest Drive, Post Office Box 2003,Simsbury,CT 06070-2003 U.S.A. TEL:(203)651-2700,FAX:(203)651-2719 <br /> BRAZIL:Sao Paulo • CANADA:Mississauga,Ontario • ENGLAND:Richmond,Surrey • FRANCE:Rungis,Celex • GERMANY:Neuhausen/Filder <br /> Printed in U.SA <br /> 576013-728 12790 Replaces 12398 VR 2/94 <br />