�> <br /> PD-847 <br /> SeNSUS SR° Water Meters <br /> METERING SYSTEMS <br /> �iUe z Magnetic give til water <br /> 1-1/2" (DN 40mm) and 2" (DN 50mm) Sizes <br /> Applications:Measurement of cold water where flow is in one <br /> direction;in residential,commercial and industrial services. 14 <br /> Conformance To Standards:Sensus Sealed Register Water <br /> Meters comply with ANSI/AWWA Standard C700,latest revision. I <br /> Each meter is tested to insure compliance. <br /> Construction:Sensus SR Water Meters consist of three basic <br /> components:maincase;measuring chamber;permanently,her- <br /> TRT <br /> metically-sealed register.Maincases are of bronze with either <br /> flanges®internally-threaded spuds.Measuring chambers are of a i <br /> Rocksyn ,a corrosion-resistant thermoplastic material.Bronze <br /> measuring chambers are available as an option. <br /> Sealed Register:Permanently,hermetically sealed;proven 1-1/2 SR' s 4 2"SR' <br /> magnetic drive design;with integral tamper-proof locking device. (DN 40mm) (DN 50mm) <br /> Guaranteed for 25 years.The standard register Includes a straight- <br /> reading,odometer-type totalization display;a 360°test circle with SERVICE Measurement of cold water with flow in only one direction. <br /> center sweep hand;and a low flow(leak)detector.Gears are self- NORMAL 1 1/2"(DN 40mm)size:5 to 100 gal/min.(1.1 to 23.0 m3h) <br /> lubricating,molded plastic for long life and minimum friction.The OPERATING 2'(ON 50mm)size:8 to 160 gal/min.(1.8 to 36.0 m3h) <br /> hermetic sealing of the register eliminates dirt and moisture.tam- FLOW RANGED <br /> pering,and lens fogging problems. ACCURACY 100%:1.5%of actual thruput <br /> No change gears are required for accuracy calibration.Encoded- LOW FLOW 1-1/2"(DN 40mm)size:95%at 1-1/2 gal/min.J0.35 m3h) <br /> type remote reading systems are available for all SR Water Meters. REGISTRATION 2"(ON 20mm)size:95%at 2 gal/min.(0.45 m h) <br /> (See back of sheet for additional information.) <br /> Tamperproof Features:Removing the register to obtain free MAXIMUM 1-1/2'(DN 40mm)3size:11.4 psi at 100 gal/min. <br /> water is prevented by a locking device inside the meter.Removing PRESSURE LOSS (0.8 bar at 23.0 m h) <br /> 2'(ON 50mm)size:12.1 psi at 160 gal/min. <br /> the register requires a special tool that is availabl�!only to water utili- (0.8 bar at 36.0 m3h) <br /> ties. MAXIMUM 150 psi(10.0 bar) <br /> Magnetic Drive:The unique design of the direct magnetic drive OPERATING <br /> is a positive,reliable,dependable drive coupling,proven in mil- PRESSURE <br /> lions of SR Water Meters. MEASURING Oscillating piston <br /> Operation:Water flows through the meter's strainer and into the ELEMENT <br /> measuring chamber where it operates the piston.The piston, REGISTER Straight reading,hermetically sealed,magnetic drive with low <br /> which moves freely,oscillates around a central hub,guided by the flow indicator. <br /> rubber-coated division plate. Remote reading unit optional. <br /> REGISTRATION 100,000,000 gallons, <br /> A drive magnet,incorporated in the piston,rotates around the out- 100 gallon/sweep hand revolution <br /> side of the hermetically sealed register well and magnetically 10,000,000 cubic feet <br /> drives the"follower"magnet sealed within the well.The"follower" 10 cubic feet/sweep hand revolution <br /> magnet drives a crank connected to the register gear train,which 100,000 m3 <br /> translate the number of piston oscillations into volume totalization 0.1 m3/sweep hand revolution <br /> units displayed on the register face. METER 1-1/2'(ON 40mm)size:two bolt oval flanged spuds or 1-1/2" <br /> CONNECTIONS® (ON 47.80mm)internal pipe threads <br /> Maintenance:Sensus Sealed Register Water Meters are engi- 2-(ON 50mm)size:two bolt oval flanged spuds or 2' <br /> neared to provide long-term value and virtually maintenance-free (59.61 mm)internal pipe threads <br /> operation because of their design simplicity and interchangeability (Threads are taped pipe,Internal type,conforming to ANSI <br /> of modules.Sensus SR Water Meters are easy to repair,even with- B1.20.1 or ISO R-7 if specified.Flanges are AWWA 125 pounds <br /> out removing the maincase from the installation.As an alternate to [PN 10 bar]class.) <br /> repair by the utility,Sensus offers various maintenance programs MATERIALS Maincase—Bronze <br /> which provide factory reconditioning of the maincase and replace- Measuring chamber—Rocksyn—standard <br /> ment of components at low fixed prices. Bronze—optional <br /> Connections:Tailpieces/Companion Flanges for installing the Magnets—ceramic and Alnico <br /> of a and sizes are available as an option. Strainer—Thermoplastic <br /> meters on a variety f�P Trim---Stainless Steel <br /> For flanged meters,the use of a Smith-Blair Mode)926 Flanged Casing bolts—Stainless Steel <br /> Coupling Adapter is recommended to facilitate the installation and <br /> r0 Maximum rales listed are for intermittent flow only.Maximum continuous flow rates as <br /> any future removal of the meter from the line. <br /> specified by A4VWA are: <br /> 1-1/2'(DN 40mm)size:50 gal/min(11.0 m3h) <br /> 2'(DN 50mm)size:B0 gal/min(18.0 m3h) <br /> Q Flanged spuds are standard for 1.1/2'(DN 40mm)and 2'(ON 50mm)size meters and <br /> will be furnished unless otherwise specified.Internal tapped pipe threads only are sup- <br /> plied for ISO meters. <br /> Page 1 of 2 <br />